approval, endorsement, sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated. 

8. 

Secure both halves of the 

AOR-TR16

 to the wall using the provided 6-32 screws, two (2) 

washers, and hex nut. 

9. 

Installation of Strobe/Siren 

Mount the strobe/siren assembly on a wall in an appropriate location per the instructions 
packaged with the strobe/siren assembly.  

10.  Three (3) outgoing low voltage power lines from the strobe/siren assembly must be wired to the 

Black, Red/White, and Orange lead wires from the relays located in the upper section of the 

AOR-8 / AOR-16 

unit

’s internal compartment

.  The Black wire is a common negative and needs 

to be connected to both the strobe and siren negative terminals.  The Red/White wire gets 
connected to the Positive terminal of the strobe and the Orange wire gets connected to the 
positive terminal of the siren. 

11.  Installing Communication Lines 

Bring in the Analog Call Station communication lines and any analog phone lines through 
conduit knockouts located on the rear, top, or bottom sides of the unit. Always try to separate 
power lines from communication lines as much as possible to reduce undesired effects on the 
phone line. 

12.  The 

AOR-8

 can support up to eight (8) Analog Call Stations.  The Analog Call Stations on the 

system can connect to either the incoming POTS/PSTN line or the local phone built into the 
AOR-8 unit. 
 
The 

AOR-16

 each support up to sixteen (16) Analog Call Stations divided into two (2) banks of 

eight (8).  The Analog Call Stations on the system can connect to either the incoming 
POTS/PSTN line or the local phone built into the AOR-16 unit. 

13.  Installing Line(s) for Analog Call Stations  

Terminate the incoming Analog Call Station lines to Ports 1-8 in the appropriate bank on the 
printed circuit board assembly (PCBA) located between the power supply and local phone.  The 
ports are labeled 1-8 for each respective bank.  See photo below. 

 

The tip and ring connections for the Analog Call Stations are polarity sensitive. 

 

 

 

Содержание AOR-16

Страница 1: ...es Analog Call Stations It is recommended that this instruction set be read completely prior to the start of any installation II Contents Please ensure receipt of each of the included AOR 8 AOR 16 components QTY Part Number Description 1 AOR 8 or AOR 16 8 or 16 Station Area of Rescue Command Unit 2 12VDC 4 5Ah Backup Battery 1 Strobe Siren Optional components sold separately include QTY Part Numbe...

Страница 2: ... distributor immediately Do not discard any hardware or packaging prior to checking for all included components listed above and the unit is installed and functioning correctly 2 Remove the three 3 Phillips screws from the right side of the unit which secure the hinged front cover shut 3 Remove the packaged front cover door handle from the telephone compartment and install to the outside surface o...

Страница 3: ...ernal compartment The Black wire is a common negative and needs to be connected to both the strobe and siren negative terminals The Red White wire gets connected to the Positive terminal of the strobe and the Orange wire gets connected to the positive terminal of the siren 11 Installing Communication Lines Bring in the Analog Call Station communication lines and any analog phone lines through cond...

Страница 4: ...de In Remote Mode pressing the button on any of the Talkaphone Analog Call Stations will cause them to access a phone line to dial out For this configuration connect an outside phone s line to the Telco IN position s on the appropriate bank NOTE See Technical Requirements p 2 for outside phone line requirements 17 Day Night Mode Day Night Mode is primarily used when a facility has a guard on site ...

Страница 5: ...w enough rings for the person answering the phone to pick up WARNING The other device sharing the line should never be emergency equipment of any kind including another bank of the AOR 16 19 Once the correct configuration for the AOR 8 AOR 16 unit has been determined and appropriately wired connect incoming 115 230 VAC 50 60Hz power wiring to the power supply board located in the bottom left of th...

Страница 6: ...successfully 2 Beeps Error s detected If you hear two beeps enter the code again If you hear two beeps a second time hang up and try again Remote Mode In Remote Mode if a standard telephone company phone line is being utilized via the Telco IN connection the consolidator does not need to be programmed Move on to Programming the Talkaphone Analog Call Stations If a PBX line is being connected to th...

Страница 7: ...r details on programming the Talkaphone Analog Call Stations refer to the Installation Operation Manual for Emergency Information Phones Note if the Consolidator is in Remote Mode or Day Night Mode and your remote phone line is a PBX extension be sure to program the emergency phones for Mode 2 See Emergency Phone Manual pages 11 and 15 for more information on Modes Code Summary Command Function 31...

Страница 8: ...l seize the line on behalf of the Analog Call Station When a call comes in to the AOR 8 AOR 16 unit an LED will light indicating which Analog Call Station is calling in If a call is already being answered any other calls which come in will cause the appropriate LED to blink to indicate they are awaiting an open line As soon as the initial call has been completed any calls that were waiting will be...

Страница 9: ...00 feet 18 AWG 1 801 3 000 feet 16 AWG 3001 5 000 feet 14 AWG Distance from AOR 8 AOR 16 Unit to Local Phone Recommended Wire Gauges 0 1000 feet 24 AWG 1001 1500 feet 22 AWG 1501 2000 feet 20 AWG 2001 3 600 feet 18 AWG 3 601 5 000 feet 16 AWG 5 001 8000 feet 14 AWG 3 I am using a consolidator in local mode Do I need to program a phone number into the Analog Call Stations You must enter a phone num...

Страница 10: ...Department 4 There isn t enough power on the line see Technical Requirements page 3 5 You may have accidentally plugged a PBX line or phone company line into the Local port If so contact Talkaphone technical support I hear noise on the line 1 You are not using twisted shielded wire Fluorescent lights elevator machinery and many other devices can produce noise on your wires if they are not properly...

Отзывы: