PRODUCT SPECIFICATION

名称

:

Installation manual for crystalline

solar photovoltaic modules(Half Cell)

SPEC.NO.

TS-ET-xx

REVISION

A0

EFFECTIVE DATE

03-2020

Page

5

of

27

Suzhou Talesun Solar Technologies Co., Ltd

Address: No. 1 Talesun Road, Changkun Industrial Park, Shajiabang Town, Changshu, Suzhou, Jiangsu Province, 215542, P.R.China

Website:

www.talesun.com

Email:

[email protected]

Tel: +86 400 885 1098

5 / 28

Do not wear metallic ornaments or metallic devices while installing or troubleshooting photovoltaic systems.

WARNING! Danger of injury due to broken glass! Risk of injury due to falling modules!

The modules are primarily made of glass and must therefore be handled with appropriate caution.

In order to ensure safe mounting, familiarize yourself with all applicable national regulations for

work safety and accident prevention.

Wear suitable protective clothing (e.g. safety shoes, protective gloves) in order to prevent injuries.

If the front glass is broken, or the back sheet is torn, contact with any module surface or the frame can cause electric
shock.

Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current and/or
voltage than reported at standard test conditions. Accordingly, the values of ISC and VOC marked on this module should
be multiplied by a factor of 1,25 1,25 when determining component voltage ratings, conductor current ratings, fuse
sizes, and size of controls connected to the PV output

Modules rated for use in this application class may be used in systems operating at greater than 50V DC or 240W, where
general contact access is anticipated. Modules qualified for safety through this part of IEC61730 and IEC61730-2 and
within this application class are considered to meet the requirements for safety class

2.2

PRODUCT PRECAUTION

Do not attempt to disassemble the modules.

Do not remove any attached nameplates or components from the modules.

Do not open the junction box under any circumstances.

Only carry out modifications to the modules that have been confirmed by Talesun in
writing in advance.

Do not carry out any extra drilling (e.g. for fasteners) on the modules.

Use only insulated tools that are approved for work on electrical installations.

Do not use light concentrators (e.g. mirrors or lenses) to attempt to increase the capacity of the module. The module
may be damaged. This also voids the warranty.

2.3 TRANSPORT AND STORAGE SAFETY GUIDELINES

Inappropriate transport and installation may break the module. To prevent damage of the modules:

Transport the modules in their original packaging until installation.

Store the modules securely in cool and dry rooms. The packaging is not weather-resistant!

Protect the modules against scratches and other damage, especially from impact at the edges or improper storage.

Ensure modules do not bow under their own weight.

Do not rest a module unprotected on its edges. This can damage the module and the frame.

Do not lift or move the modules using the cables or at the junction box under any circumstances!

Do not set the modules down hard on any surface.

Do not subject the module surfaces to mechanical stress.

Содержание TP6L60M-320

Страница 1: ...ebsite www talesun com Email sales talesun com Tel 86 400 885 1098 REVISIONS Suzhou Talesun Solar Technologies Co Ltd REV ECN NPA DESCRIPTION OF CHANGE CHK D DATE APP D DATE TITLE Installation manual...

Страница 2: ...of 27 Suzhou Talesun Solar Technologies Co Ltd Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales...

Страница 3: ...28 INDEX 1 INTRODUCTION 1 1 PURPOSE OF THE MANUAL 1 2 DISCLAIMER OF LIABILITY 1 3 PRODUCTION IDENTIFICATION 2 SAFETY GUIDELINES 2 1 GENERAL SAFETY GULDELINES 2 2 PRODUCT PRECAUTION 2 3 TRANSPORT AND S...

Страница 4: ...eaning This manual and the instructions set forth herein are part of the product and should therefore be kept for the entire useful life of the solar installation Information for operators Keep these...

Страница 5: ...TY GUIDELINES DANGER Danger due to electric shock All installations must be performed in compliance with all applicable regional and local codes or other national or international electrical standards...

Страница 6: ...for use in this application class may be used in systems operating at greater than 50V DC or 240W where general contact access is anticipated Modules qualified for safety through this part of IEC6173...

Страница 7: ...nti salt function when the distance is between 100m and 1km A module is considered shade free when it is entirely unshaded throughout the year e g by buildings chimneys trees Even partial shading of t...

Страница 8: ...mended standoff height is 10cm Clearance of 1 4 of an inch 6 35 mm or more between modules is required to allow for thermal expansion of the frames For roof mounting applications the assembly is to be...

Страница 9: ...ture Use appropriate corrosion proof fastening materials All mounting hardware bolt split washer flat washer nut should be stainless steel M8 size And the parts in contact with the frame should use th...

Страница 10: ...not mounted following the instructions above b Clamping installation Modules can be installed with clamps Modules must be securely attached to the mounting structure with four clamps on the long fram...

Страница 11: ...pe Module Dimension Length Width Thickness Load A Distance from module edge to clamping zone B Clamping zone TP6L72 H series 2098mm 1046mm 35mm Negative 1600Pa 440mm 100mm Positive 3600Pa 440mm 100mm...

Страница 12: ...r need to pay more attention to avoid the PID phenomenon when installing the electrical system 4 3 GENERAL INSTALLATION Before installing modules contact the appropriate authorities to determine permi...

Страница 13: ...oid the PID phenomenon of the module in addition and professional person is needed to undertake the polarity negative ground operation of the inverter If the support frame is made of metal the surface...

Страница 14: ...1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 13 28 frame The recommende...

Страница 15: ...VISION A0 EFFECTIVE DATE 03 2020 Page 14 of 27 Suzhou Talesun Solar Technologies Co Ltd Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R C...

Страница 16: ...exchange is made by an authorized person Protect yourself from electric shocks while debugging or maintaining the solar power system Bypass diode type Manufacturer Schottky GF2545MG Shandong DIYI Sci...

Страница 17: ...s Type 6inch 3inch 144cells Mono crystalline 6inch 3inch 120cells Mono crystalline Dimension mm 2098 1046 35 1758 1046 35 Weight kg 25 5 21 Module Maximum System Voltage V Pmax W Vmpp V Impp A Voc V I...

Страница 18: ...ng A TP6L60M 375 1000 IEC 375 35 2 10 66 41 3 11 31 20 TP6L60M 370 1000 IEC 370 34 9 10 61 41 1 11 26 TP6L60M 365 1000 IEC 365 34 6 10 56 40 9 11 20 TP6L60M 360 1000 IEC 360 34 3 10 50 40 7 11 15 TP6L...

Страница 19: ...oltage V Pmax W Vmpp V Impp A Voc V Isc A Fuse Rating A TP6L60M H 375 1500 IEC 375 35 2 10 66 41 3 11 31 20 TP6L60M H 370 1500 IEC 370 34 9 10 61 41 1 11 26 TP6L60M H 365 1500 IEC 365 34 6 10 56 40 9...

Страница 20: ...Tokyo Japan 105 0001 Email japan talesun com Web www talesun com jp T 03 5733 3498 F 03 34341515 USA 25 METRO DRIVE Suite 228 San Jose CA 95 110 USA Email sales talesun com Tel 408 638 7627 Fax 408 64...

Страница 21: ...age 20 of 27 Suzhou Talesun Solar Technologies Co Ltd Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email...

Отзывы: