10. DMX General Information 

 
The DMX512 digital communication protocol was introduced to control 
stage lighting and special effects. 
 
The DMX standard features 512 available channels, and they are 
assignable in any sequence that conforms to the user's needs. Each DMX-
capable fixture requires one or more sequential channels. A starting 
address, which indicates the first control channel reserved for that 
particular fixture, must be assigned to the fixture before the controller can 
recognize it. DMX controllable fixtures may vary in the number of 
channels they require, depending on the fixtures features and/or 
functionality.  
 
Channels should never be permitted to overlap; otherwise, for example, a 
fader that controls blue output on one fixture may cause strobing or 
dimming on an adjacent, incorrectly assigned fixture. Multiple fixtures of 
the same type that use an identical starting address will function in unison. 
Fixtures assigned properly spaced starting addresses will operate 
individually, but a DMX controller with sufficient channels can be 
configured to run these same fixtures either combined or independently.  
 
The sequence in which DMX fixtures are connected has no effect on how 
a controller communicates with each individual lighting fixture. Although 
3-pin XLR mic cables may be used to connect DMX fixtures over short 
runs, longer distances will introduce data errors due to the mic cable's 
incorrect impedance. For best results, Talent Sound & Lighting 
recommends the use of correct 120 ohm, low-capacitance, twisted pair 
cable designed for the DMX512 protocol. It is also suggested that a 
termination resistor plug be used on the output connector of the last fixture 
in an array of DMX instruments. This resistance ensures proper data 
transmission.

 

 
 
 

 
 
 
 
 

 

Notes 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание LP64LED-FLAT

Страница 1: ...1 Safety Instructions 2 Technical Specifications 3 Installation 4 How to Connect the Fixture 5 DMX512 Connections 6 How to Set the Unit 7 DMX Configuration 8 IR Remote Control 9 Troubleshooting 10 DMX General Information ...

Страница 2: ...might be a hazard of electrical shock To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture The fixture must be replaced if there is visible damage to the housing Do not look directly at the LED light beam while the fixture is on Warning Please read the instructions carefully They include important information about installation operation and maint...

Страница 3: ...till require unit to unit connection by proper DMX cables Caution Common microphone cables may be used to connect small numbers of DMX fixtures over short distances but offer the risk of erratic operation Use of correct DMX cables greatly reduces data errors caused by improper connection If you are using a controller with 5 pin DMX output use a 5 pin to 3 pin adapter cable Connect fixtures togethe...

Страница 4: ...run the chase the fixtures in the chain will set the series DMX address automatically Each lighting fixture needs to have an address set when in DMX mode to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 Please refer to the following diagram to set the address for the first four units The numbers 1 5 9 and 13 indicate the starting address of ...

Страница 5: ...on DMX Channel Values 3 Channel Mode DMX Channel Values 5 Channel Mode DMX Channel Values 7 Channel Mode For additional details about DMX operation please review Section 10 8 IR Remote Control 8 1 IR Remote Control Keypad ...

Страница 6: ...X polarity 3 If you have intermittent DMX signal problems check the pins on the cable connectors and on the fixture 4 Try to use a different DMX controller 5 Interference may occur if DMX cables are run alongside high voltage cables C Fixture responds erratically to DMX control 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX addr...

Страница 7: ...acent incorrectly assigned fixture Multiple fixtures of the same type that use an identical starting address will function in unison Fixtures assigned properly spaced starting addresses will operate individually but a DMX controller with sufficient channels can be configured to run these same fixtures either combined or independently The sequence in which DMX fixtures are connected has no effect o...

Отзывы: