background image

Problem

Cause

Solution

Unit will not run

Mechanical obstruction 

or Motor obstruction

Remove obstruction and press down on cup head several times to confirm no obstruction exists. If 

problem persists, please contact your Talboys representative for repair. 

Unit is excessively noisy

Sensor fan misaligned  

or Motor misaligned 

This error cannot be fixed by the end user. Please contact your Talboys representative for repair. 

t

roublesHooting

10

Содержание Basic Vortex

Страница 1: ...Instruction Manual Basic Vortex Mixer Standard Vortex Mixer Advanced Vortex Mixer Pulsing Vortex Mixer Instruction Manual...

Страница 2: ..._____________ Package Contents Fixed Speed Analog Digital or Pulsing Vortex Mixer 72 183cm power cord 1 cup head 1 3 7 6cm head 1 3 7 6cm rubber head cover Instruction manual Warranty card These acces...

Страница 3: ...r check to ensure that no damage has occurred during shipment It is important that any damage that occurred in transport is detected at the time of unpacking If you do find such damage the carrier mus...

Страница 4: ...power supply prior to maintenance and servicing Spills should be removed promptly Do not immerse the unit for cleaning Do not operate the unit if it shows signs of electrical or mechanical damage Ear...

Страница 5: ...peed 2500rpm Analog Vortexer Mixer Specifications Overall dimensions L x W x H 8 x 5 x 5 25 20 3 x 12 7 x 13 3cm Electrical 50 60 Hz 120V 1 2 amps 150 watts 230V 0 6 amps 150 watts Speed range 300 to...

Страница 6: ...time is remaining timed mode The display range is from 0 to 9 999 minutes in one 1 second increments The display will indicate minutes and seconds until the timer reaches 99 minutes and 59 seconds 99...

Страница 7: ...wall outlet 1 Make sure the 3 way rocker switch is in the center off position Plug the power cord into a properly grounded outlet 2 For continuous operation push the rocker switch to the right on posi...

Страница 8: ...zero 0 00 To run in continuous mode accumulated time reset the timer to zero 0 00 before running Time display will show the accumulated time and run until you press the rocker switch to the center sta...

Страница 9: ...ress center of head down firmly until it snaps into place DO NOT use a 3 head without the 3 rubber head cover Add samples to attachments after the head is secured onto the Vortex Mixer Be sure samples...

Страница 10: ...ill hold the Single Tube Holder in place To realign this attachment pull up from the handle until the magnets release check the alignment and place again 4 Now that the Single Tube Holder is in place...

Страница 11: ...on cup head several times to confirm no obstruction exists If problem persists please contact your Talboys representative for repair Unit is excessively noisy Sensor fan misaligned or Motor misaligne...

Страница 12: ...l for mixing up to 8 50mL centrifuge tubes Requires Insert Retainer Description Part Number 20 to 25mm Tube Holder 2 pk 945636 Insert Retainer 945631 Flat Foam Insert Ideal for custom applications Can...

Страница 13: ...taches to the top of any Vortex Mixer with the use of a strong magnetic base Accepts tubes from 2 5 to 4 5 6 4 to 11 4cm in length Minimum tube diameter of 0 75 1 9cm Part Number 945659 0 5mL Micro Tu...

Страница 14: ...201 Wolf Drive PO Box 87 Thorofare NJ 08086 Phone 1 888 TALBOYS Fax 856 686 1601 E mail troemner troemner com www troemner com 715027 00 REV 6 8 14 Manufactured by...

Отзывы: