When the unit is mounted on unlebel wall,back 
tamper switch could be kept turninig on. In this case, 
use B.T.Killer which can disable the function ©.

7

 WIRING

Terminal Confi guration

[COMMON BATTERY]

Common for TX-114TR/FR/SR and Transmitter

 

 When  connecting  this  unit  to  the  transmitter 
which has no input terminals for tampers, connect 
alarm and tamper terminals of this unit in series.
Both alarm and tamper signals can be outputted. 
(Select N.C. for contact output.) 

SUPPLY VOLTAGE

•3 to 9VDC Alkaline or Lithium Battery (polarity)
•Current Consumption

(Except test-mode period) 
25 μA (TX-114TR/114SR)
35 μA (TX-114FR)

• When a connected transmitter doesn’t accept the 

output, to short curcuit between    terminal of this 
unit and the negative pole of the battery for the 
transmitter may solve the problem.

ALARM

•Solid State Switch form N.O./N.C. selectable
•10VDC · 0.01A Max

[Detection Alarm]

 OR 

[Trouble Alarm]

TAMPER

•Solid State Switch form N.O./N.C. selectable
•10VDC · 0.01A Max

[Front Tamper]

 OR 

[Back Tamper]

[SEPARATE BATTERIES] 

Each for TX-114TR/FR/SR and Transmitter

 

 Powersupply needs same or higher voltage than 
that for transmitter

 

 When a connected transmitter doesn’t accept the 
output, to connect the    terminal of TX-114TR/
FR/SR and the negative pole of the battery for the 
transmitter may solve the problem.

Wiring insertion

|

|

(1)

  Put the wire through the wiring holes and connect 

them to the battery and transmitter and the 
terminals.

(2)

  Fix the transmitter and battery on the back box 

with the adhensive sheets.

* When connecting this unit to the transmitter which 

has no input terminals for tampers, connect alarm 
and tamper terminals of this unit in series.
Both alarm and tamper signals can be outputted.
(Select N.C. for contact output.)

8

 INSTALLATION

Before the installation

|

|

Read 

 2 

 

PRECAUTIONS

 before the installation.

(1)

 Loosen the cover locking screw.

(2)

 Remove the cover.

(3)

 Loosen the body locking screws. 

(TX-114TR/114FR only)

(4)

 Remove the body unit. (TX-114TR/114FR only)

Wall Mounting

|

|

TX-114TR/114FR

(1)

 Break 2 knockouts on the mounting base.

(2)

 Install the base to the wall with 2 tapping screws.

[Installed pitch: 3.29" (83.5mm)]

TX-114SR

(1)

 Install the base to wall with 2 tapping screws.

[Installed pitch:8.25" (209.5mm)]

Pole Mounting 

|

|

TX-114TR/114FR

Use the pole attachment "BP-32" (sold separately)
Use a 1.66" to 1.75" (38mm to 45mm) outer diameter 
pole

(1)

 Break 4 knockouts on the mounting base.

(2)

  Attach 2 pole mounting brackets to the backside 

of the base with 4 tapping screws.

(3)

 Place the U brackets on the back of the pole.

Attach the mouting base to the U bracket with 
pole mounting screws.

(4)  Refer  to 

 7 

 

WIRING

 and connect wires to the 

terminals.

TX-114SR

Use the pole attachment "BP-22" (sold separately)

A

B

C

Assembling 

|

|

(1)

  Attatch the Body unit to the Mounting Base. 

(TX-114TR/114FR only)

(2)

 Fasten the Body locking screws. 

(TX-114TR/114FR only)

* Carry  out 

OPERATION CHECK

 with the cover 

detatched.

(3)

 Replace the cover.

(4)

 Fasten the Cover locking screw.

OPERATION CHECK

• 

Refer to the 

 3 

 

DETECTION AREA

, and set the 

horizontal angle and detection distance.

• Make  functional  settings  in  accordance  with  the 

purpose of use of this unit.

SPECIFICATIONS

Model

TX-114SR

TX-114TR

TX-114FR

Detection system

Passive infrared

Coverage

When horizontal detection
Angle: 90°
Detection distance: 40' (12m)
Horizontal zone: 7zones
Downward zone: 7zones

2sets of 

TX-114SR / TX-114TR 

sensors

Coverage adjustment

Horizontal: 90 degrees
Detection distance: 6.6' to 40' (2m to 12m)
(Adjustable by changing the vertical angle of downward curtain)

Supply voltage

3V to 9VDC Alkaline or Lithium Battery

Operation voltage

2.3V to 10VDC (Battery)

Current consumption

25 

μ

A for detection

35 

μ

A for detection

5mA/3V (Test mode)

Operation

Solid State Switch N.C./N.O. selectable
10VDC · 0.01A Max

z

Alarm output

|

|

One shot output when detecting human beings (approx. 2sec)

z

Tamper output

|

|

Real time output

when the cover is detatched from the unit

when the unit is detatched from the installed wall or pole. (TX-114TR/TX-114FR Only)

z

Trouble output

|

|

Real time output when the unit suffers functional trouble. (from terminal of Alarm)

Operation LED

Red LED

Blinking for approx. 1min at warming-up

Lighting for 1sec at detection during walk-test (LED lights only in a test-mode)

Blinking when trouble alarm is issued (Lights once every 5 sec)

Sensitivity adjustment

Approx. 30% to 170% (By volume)

Pulse count

1/3 selectable with a dip switch

Alarm prohibition time

10sec/120sec/300sec/900sec selectable with dip switches

Detection mode

AND/OR selectable

Ambient temperature

-4°F to +122°F (-20°C to +50°C)

Mounting position

Indoor/Outdoor [Wall or Pole]

Weight

14oz (400g)

19.6oz (560g)

21.7oz (620g)

Appearance

Body: AES resin     Lens: PE resin

TROUBLESHOOTING

Trouble

Check

Corrective Action

Completely inactive

Battery is unconnected or low battery.

Connect battery or replace battery.

 Cover is shielded by substances (including 
glass).

Remove the substances.

Improper area adjustment.

Readjust the protection area setting.

Not yet about 1minute after a battery is connected 
to the unit. (Operation LED is 

fl

ickering.) 

Allow for warming up time (about 1min.)

 The voltage of powersupply is lower than that 
for transmitter.

Use same or higher voltage than transmitter.

Incorrect polarity of powersupply

Change the polarity.

Improper setting of output form

Select the correct setting.

Sometimes inactive

Improper area adjustment.

Readjust the protection area setting.

Cover face is soiled with dust or water drop.

Clean the cover with soft cloth.

 Detection occurs within the signal prohibition 
time set by a dip switch.

 If the sensor sends a signal after the 
prohibition time is over, its function is normal.  

Activated when no person
has passed 

 Something moving in protected area or too 
rapid temperature variations.

Remove the cause.

Large electrical noise source such as power 
machine nearby or its wiring close to that of 
sensor.

Relocate device.

• 

Intense re

fl

 ection of sun light or head light 

shining on the sensor.  

 Relocate device. Readjust the protection area 
setting. 

 Re

fl

ective lights such as sun light or head 

light affect the downward zone.  

Remove re

fl

 ective objects. 

Readjust the protection area setting.  

Improper installation of the sensor.

Install the sensor vertically.

Detection distance of the downward zone is too long. 

Readjust detection distance.

 Cars or motor bikes located at the front of 
detection area may activate the sensor.

Readjust the area setting and range adjustment 
so that there is no such undesirable detections.

LED lights on once every 
5 min though the unit is 
not in a test mode 

The unit suffers functional trouble. (Trouble 
signal is issued.) 

Check the function of the sensor.

Solve possible problems according to the following  table.  If  normal  operations  cannot  be 
 restored by this means, contact either the dealer from whom you bought the unit or TAKEX.   

• Connect the battery to the unit after which approx. 

1 min warm up period starts.

• Attach the cover to the unit and fi x it by tightening 

the cover locking screw.
(After the warm up time is over and the cover is 
attached to the sensor, the unit will be in a test mode 
for about 5 min.)

• After the warm up time is over, operate a walk test 

and check the location and size of the detection area 
through the LED.

• If necessary, readjust the angle and distance of 

the detection area as well as sensitivity and pulse 
count.

* Make sure that there is no undesirable detection of 

traffi c including vehicles if there is a path or road at 
the front of detection zone.

Limited Warranty:

TAKEX products are warranted to be free from 
defects in material and workmanship for 12 months 
from  original  date  of  shipment.  Our  warranty  does 
not cover damage or failure caused by Acts of God 
(including inductive surge by lightning), abuse, 
misuse, abnormal usage, faulty installation, improper 
maintenance or any repairs other than those 
provided by TAKEX. All implied warranties with 
respect to TAKEX, including implied warranties for 

merchantability and implied warranties for fi tness, 
are limited in duration to 12 months from original date 
of shipment. During the Warranty Period, TAKEX 
will repair or replace, at its sole option, free of charge, 
any defective parts returned prepaid. Please provide 
the model number of the products, original date of 
shipment and nature of diffi culty being experienced. 
There will be charges rendered for product repairs 
made after our Warranty period has expired.

Содержание TX-114FR

Страница 1: ...ornillo de montaje S Battery holder Soporte de bater a T Battery Leads Cables para la bater a U Back Tamper killer Tamper trasero killer A Operation LED LED operacional B Lens Lente C Cover locking sc...

Страница 2: ...90 Giro 15 90 15 pitch 90 Giro 15 Sensor Away from the wall Alejado de la pared s 4OWARDS THE WALL s ACIA LA PARED ALARM ALARMA NO ALARM SIN ALARMA NO ALARM SIN ALARMA 2 PRECAUTIONS PRECAUCIONES 2 6 4...

Страница 3: ...SR TX 114FR 90 Detection distance is set by adjusting the angle of downward zone Adjustable range 6 6 2m to 40 12m 10 ranges La distancia de detecci n se establece mediante el ajuste del ngulo de la z...

Страница 4: ...nsor TX 114FR tiene dos juegos de los anteriores interruptores para el sensor superior e inferior Warm up period Test mode function Detection signal Trouble alarm Front Tamper signal Cover removal Bac...

Страница 5: ...5mm 2 0 18 4 70 4 59 3 04 119 5mm 77 25mm 3 29 83 5mm 116 5mm 3 58 9 65 Back tamper Anti sabotaje trasero 91mm 245mm MOUNT HOLE ORIFICIO DE MONTAJE TX 114TR 114FR TX 114SR TX 114TR 114FR 9 21 234mm 3...

Страница 6: ...ES The following factors may have an effect on the actual detection range or sensitivity The greater the distance covered the more prominent this effect becomes Ambient temperature vs object temperatu...

Страница 7: ...LED Blinking for approx 1min at warming up Lighting for 1sec at detection during walk test LED lights only in a test mode Blinking when trouble alarm is issued Lights once every 5 sec Sensitivity adju...

Страница 8: ...izontal Al alejar la zona de detecci n de la pared deslice la palanca hacia la pared Al acercar la zona de detecci n a la pared deslice la palanca en direcci n contraria a la pared 4 AJUSTE DE LA DIST...

Страница 9: ...e en pared TX 114TR 114FR 1 Rompa 2 de los ori cios pretroquelados en la base de montaje 2 Instale la base en la pared con 2 tornillos roscado res Inclinaci n instalada 3 29 83 5 mm TX 114SR 1 Instale...

Страница 10: ...lexi n intensa de iluminaci n solar o foco reflejado en el sensor Cambie la colocaci n del dispositivo Reajuste los ajustes del rea de protecci n Las luces reflectoras como la luz solar o los focos af...

Страница 11: ...Kyoto 607 8156 Japan Tel 81 75 501 6651 Fax 81 75 593 3816 http www takex eng co jp Takex America Inc 3350 Montgomery Drive Santa Clara CA 95054 U S A Tel 408 747 0100 Fax 408 734 1100 http www takex...

Отзывы: