Takex PXB-100SW Скачать руководство пользователя страница 10

–10°

+10°

Coarse adjustments

+90°

+5°

–90°

–5°

–10°

+10°

Names of the Operation Section

Note: This section describes the name and function of each part used during optical axis adjustment.

Upper transmission/reception authorization LED

Lower transmission/reception authorization LED

Each time the switch is pressed, the optical unit that transmits the light switches.

Transmitter

Receiver

Upper/lower changeover switch

Swing arm
(Red)
Note: For vertical 

angle 
adjustments

Horizontal angle fine adjustment screw
(White)
Note: For horizontal angle adjustments

Vertical angle adjustment screw
(Red)
Note: For vertical angle 

adjustments

Swivel base
(White)
Note 1: For horizontal angle 

adjustments

Note 2: Single notch is 

equivalent to 3°

Near

Far

Note: Sequence of 

adjustment

Near

Far

When the view finder is 
looked closely, view appears 
as the diagram on the right.
Adjust the angle so that the 
target color appears in the 
center of the ring. 

When the view finder is 
looked from a distance, the 
view appears as the diagram 
on the right.
Adjust the angle so that the 
target color appears in the 
center of the ring. 

(High accuracy)

Double Ring Alignment Mechanism 
Visible from the view finder

6-1

NAMES AND FUNCTIONS OF OPTICAL AXIS ADJUSTMENT PARTS

OPTICAL AXIS ADJUSTMENT

Names of the Optical Unit

View finder

Horizontal

Reflector Section Horizontal/Vertical Angle Adjustment Method

Vertical

Coarse adjustments can be made 
by moving the swivel base 
within the range of 0˚ to ±90˚.

Next, fine adjustments of 0˚ to ±5˚ 
can be made using the horizontal 
angle adjustment screw.

Fine adjustments

Horizontal angle fine 
adjustment screw

Coarse adjustments

Fine adjustments

The inclination of the reflector can 
be switched between -10˚ and +10˚ 
by pushing it forwards or 
backwards.

Next, fine adjustments of 0˚ to ±10˚ 
can be made using the vertical angle 
adjustment screw.

6

By aligning the optical axis correctly, a protection line with sufficient margin 
of sensitivity can be created, reducing the occurrence of malfunction. 
Always adjust the optical axis on both upper and lower levels.

Alarm LED
Note: Only available 

on the receiver

• Lights up when an 

alarm is output.

Sensitivity attenuation 
LED
Note: Only available on 

the receiver

• Lights up when the 

sensitivity is 
insufficient.

The corresponding LED lights up when the 
light transmission/reception is authorized. 
(The upper and lower can be switched by 
he upper/lower changeover switch.)

Transmit from both upper and lower

Only transmit 
from upper

Only transmit 
from lower

No transmission

Received on both upper/lower

Only received on lower

Only received on upper

Each time the switch is pressed, the optical unit that receives the light is switched.

Monitor jack Note: Only available on the receiver
    • The monitor output voltage can be checked by using a commercially available tester.
Sound check switch Note: Only available on the receiver
    • Light reception level can be checked by the sound tone.
      In the walk test mode, the beep sound is generated according to the alarm output.
Channel change over switch 

 Installed on the transmitter and receiver (Factory setting : 1CH)

Содержание PXB-100SW

Страница 1: ...ansmitter with the receiver is the detection line If the detection line is obstructed light is obstructed for more than 0 05 0 7 seconds the receiver detects this break in the light beams and outputs...

Страница 2: ......

Страница 3: ...Factory setting N C 8 EXPLANATION OF FUNCTIONS 8 8 ENVIRONMENTAL OUTPUT SELECTION FUNCTION Environmental output changeover switch Factory setting N C Light reception channel changeover switch Factory...

Страница 4: ...0 8m from the ground means that the protection line is at waist height for humans enabling reliable detection If the installation position is too high or too low the protection line will be above sho...

Страница 5: ......

Страница 6: ......

Страница 7: ...to Caution A B If the plate is removed the plate will also fall off the pole When replacing the sensor keep both plates to the pole and replace only the sensor unit...

Страница 8: ......

Страница 9: ...r 1CH Transmitter 1CH Receiver 1CH Transmitter 3CH Receiver 3CH Receiver Receiver Receiver RF transmitter RF transmitter RF transmitter RF transmitter RF transmitter Basic connection 1 zone connect al...

Страница 10: ...ange of 0 to 90 Next fine adjustments of 0 to 5 can be made using the horizontal angle adjustment screw Fine adjustments Horizontal angle fine adjustment screw Coarse adjustments Fine adjustments The...

Страница 11: ...djust so that the sensor of the opposite device is visible at the center of the ring using the horizontal and vertical angle fine adjustment screws Turn on the power to the transmitter and receiver ch...

Страница 12: ...itter to select Only transmit from upper 2 Press the upper lower changeover switch on the receiver to select Reception authorization on upper only 3 Turn the adjustment screw to fine adjust until the...

Страница 13: ...smit from lower 2 Press the upper lower changeover switch on the receiver to select Reception authorization on lower only 3 Turn the adjustment screw to fine adjust until the monitor output voltage re...

Страница 14: ......

Страница 15: ...ON OFF...

Страница 16: ...the light reception level for both the upper and lower beams recovers to the specified level for 5 seconds at the shortest Using the alignment wireless checker that is sold separately enables easy an...

Страница 17: ...d or cat may obstruct the beams 9 Transmission power switch is set to L which does not keep enough margin of sensitivity 1 Check again 2 Stabilize the supply voltage 3 Remove the object 4 Change the w...

Страница 18: ...2 Receiver Max 3 1mA 1 Max 10 7mA 2 10 to 30V DC Dry contact relay output N C N O switchable Contact action Interruption time Min 2sec Contact capacity 30V AC DC 0 25A resistive load Protective resis...

Страница 19: ......

Страница 20: ......

Отзывы: