Do not install the unit in places
where it may be affected by rain.
●
Do not blind the unit by placing
any object in the detection area.
●
Keep installation height within
13' (4m).
●
Adjust the detection area after
installation.
2
3
DETECTION AREA
DO'S AND DON'T'S
1. DETECTION AREA
2. ADJUSTMENT
1. When the unit is soiled, clean the cover with a soft cloth
moistened with a small amount of cleansing-solution. Do not
use chemicals such as thinners or alcohol.
2. Check operation once a week. Do not fail to check operation
whenever furniture in coverage area is moved.
1. Set the pattern selector to double or
single door by Pattern Selector.
2. Set the arrow of the angle adjusting
lever to detection area.
The arrow of the angle adjustment
lever points to the detection area.
3. Walk test the unit to ensure proper
detection pattern.
4. Check the functioning of the unit once
a week. This check should also be
carried out whenever the detection
area has been altered.
●
The PS-520E is designed to detect infrared energy variations
caused by the presence of a human body. Therefore, note that
similar variations in conditions in the detection area, due to
other reasons, may cause the sensor to create an output as it is
unable to distinguish between source.
(2.4m)
(0.6m)
ADJUSTABLE
(8 steps)
(5 steps)
ADJUSTABLE
20°
(4m)
13'
(3m)
9.75'
(2m)
6.5'
35°
0.8'
(0.25m)
(0.25m)
0.8'
8'
(1.2m)
4'
2'
(1.2m)
4'
(4m)
13'
(3m)
9.75'
(2m)
6.5'
(4m)
13'
(0.5m)
1.6'
1.6'
(0.5m)
[FRONT VIEW]
[SIDE VIEW]
(CEILING)
DOUBLE DOOR
WALL&FRAME MOUNT
SINGLE DOOR
OVERHEAD MOUNT
[MAINTENANCE]
Angle Adjusting Lever
Pattern Selector
Double
1.6' (0.5m) away from door
Single