⑥
No
Alarm detection
Low supply voltage**
LED operation
Status
Recovery
Blinking (approx. 1min)
Blinking rapidly
Blinking slowly
Lights (approx. 2sec)
Lights continuously
-Mode setting “8” ON : Left and Right
-Mode setting “8” OFF : Left or Right
Warm-up
Masking detection
Self diagnosis error*
Walk test
Operation
0.15
0.15
0.85
0.5
0.15 0.15
0.15 0.15
0.1
0.1
0.6
(1) Replace the cover to automatically start the operation check and walk test function (for 5 min) after 1 min of LED blinking.
(2) Check that the LED lights on both detection side (left and right) within the set detection area.
(3) Readjust the detection area if necessary.
(4) Anti-masking performs learning function for 3 min after cover is replaced. For this to be successful, do not have any object within
10cm of the lens during this period.
(5) Check also operation of connected devices, when applicable.
MAINTENANCE
1. Clean the device with a soft, damp cloth and wipe off water drops. Use water with weak neutral detergent to clean stubborn dirt.
Do not use substances such as thinner or benzene.
2. Perform operation check on a regular basis.
(1) No power supply (including broken wiring), or the
power supply voltage is low.
(2) The detection area is blocked by an object (which may
include glass).
(3) Unsuitable detection area settings (including
detection distance).
(4) Approximately 1 minute has not passed since turning
the power ON.
(1) Check the power wiring, and power supply voltage.
→
>
:,5,1*@
(2) Remove obstacles.
(3) Readjust detection area.
→
>
6(77,1*@
(4) Wait approximately 1 minute.
(1) Unsuitable detection area settings (including
detection distance).
(2) The detection lens is covered with dust or water droplets.
(3) Unsuitable detection or pulse count settings.
(1) Readjust detection area.
→
>
6(77,1*@
(2) Clean the lens with a damp soft cloth, and wipe off
water droplets.
(3) Readjust the settings.
→
>
6(77,1*@
(1) Wiring failure, broken wire, or short-circuit.
(2) Check that connected devices are operating correctly.
(1) Connect wiring correctly.
(2) Investigate with reference to the instruction manuals
of the connected devices.
(1) Unstable power supply voltage.
(2) Something is moving within the detection area, or
there are sudden changes in temperature.
(3) A source of electrical noise (broadcasting station,
amateur radio station, etc.) is nearby.
(4) Direct or reflected light such as sunlight or headlights
sometimes shines onto the sensor itself or into the
detection area.
(5) The sensor is mounted on an angle (the horizontal
zone is tilted).
(6) Cars or motorcycles are sometimes detected at the
edge of the detection area.
(1) Ensure appropriate power supply voltage.
(2) Identify the problem object, and remove it.
(3) Change the mounting location or remove the noise
source.
→
>
35(&$87,216@
(4) Change the mounting location, or location of the
reflective item.
Readjust detection area.
Use the area masking sheet to hide zones for which
detection is not required.
→
>
6(77,1*@
(5) Change the mounting location.
→
>
6(77,1*@
(6) Reduce the set distance. Readjust detection area.
→
>
6(77,1*@
Trouble
Check
Corrective Action
The sensor does not
detect anything
The sensor sometimes
does not detect anything
The sensor generates
an alarm, although
there are no people
within detection area
The operation LED is on,
but connected devices are
not operating.
Solve possible problems according to the following table. If normal operations cannot be
restored by this means, contact either the dealer from whom you bought the unit or TAKEX.
0.5
0.5
*Detection and notification of the problems caused by broken wiring inside the sensor, malfunction, etc.
**Monitoring and notification in case input power supply voltage to the sensor is reduced.
Detect twice after 15 seconds after
opening and closing the cover.
Return to the normal status by
power supply reset
Return to the normal voltage by
power supply reset
[sec]
[sec]
[sec]
(LED’s corresponding to left/right zones)
2SHUDWLRQFKHFN
/('LQGLFDWLRQ
&+(&.,1*
7528%/(6+227,1*