COVERAGE

5

INSTALLATION

Terminal arrangement

Power (non-polarity)

9V to 30VDC 30mA

POWER

COM N.C.

TAMPER

Tamper (N.C.)

Opens when cover is detached

Alarm

Dry contact relay (N.C.)

Turn round when an alarm is initiated.

Capacity : 30V (AC/DC) 0.1A or less

Reset : approx. 2 sec.

Allowable wiring distance between sensor and power source

  Size of wire used

AWG 22 (

φ

0.65mm)

AWG 20 (

φ

0.8mm)

AWG 18 (

φ

1.0mm)

Distance at 12VDC

  250m (830 ft.)

  450m (1460 ft.)

  700m (2300 ft.)

The  maximum  wire  length,  when  two  or  more  units  are 
connected,  is  the  above  distance  divided  by  the  number  of 
units.
The  protection  circuit  can  be  wired  to  a  distance  of  max. 
1,000m (3,300 ft) with AWG 22 (

φ

0.65mm) wire.

Horizontal direction

Use  the  Microphone  holder  to  set  a  coverage  that  corresponds  to 
the installing position. (Adjustable by  40º)

(1) Installation

(2) Wiring

(3) Area setting

The  coverage  indicated  in  the  diagram  does  not 
have  surrounding  walls  or  other  objects  that 
would reflect ultrasonic waves, and the sensitivity 
volume is turned all the way to H.

Install  the  sensor  so  that  sensor  coverage  could 
cover  all  surface  of  protected  window.  For 
reference,  glass  surface  to  be  protected  is  5m  or 
less square.

Confirm the install position of the sensor and the 
position  of  the  surface  of  protected  window. 
Determine  the  optimal  area  angle,  and  use  the 
Microphone holder inside the sensor to set it.

Loosen cover locking screw to detach cover.

Check protection direction and install base on wall.

Break  knockouts  and  attach  sensor  with  supplied 
screws.

Connect as per wiring diagram 5. (2). 

Set coverage and check operation. 
Refer to 5. (3) Area setting and 6. 
Operation check.

Replace cover and tighten cover locking 
screw.

Rotate  Microphone  holder 
to  set  area  direction  to 
center of protected glass.

80

°

(Area adjustable range)

[TOP VIEW]

6m [20ft]

3m [10ft]

3m [10ft]

6m [20ft]

4m [13ft]
3m [10ft]

3m [10ft]
4m [13ft]

8m

6m

3m

[20ft]

[10ft]

[26ft]

[SIDE VIEW]

8m

[26ft]

6m

[20ft]

3m

[10ft]

2 pitches 76mm (3") or 

83.5mm (3.29") are available 

for mounting hole.

Mounting hole.

Knockout

(Break with slender-driver)

Mark  pitch by 10

°

Microphone

holder

Center

Direction of

area

Note 1)

2)

(                                             )

6

OPERATION CHECK

7

OPERATION DESCRIPTION

EG-2000 operation

(Output selector "L")

Alarm generating sound

(EG-2000 operation Output selector "H")

Other device 

activation

High sens.

47min. ON

3min. flashing

Low sens.

Good sens.

Success in noise test 

Adjustment completed.

Environmental LED (Orange)

Environmental LED (Orange)

Alarm LED (Red)

Alarm output

Alarm LED (Red)

Alarm output

approx. 2 sec.

Check mode

Select "Check" mode for operation check and sensitivity adjustment.

In this mode, both environmental LED (Orange) and alarm LED (Red) activate.

Operation mode

When the unit has been activated the Alarm LED will flash for 3 minutes, and then it will remain constantly lit for 

47 minutes.

This will enable identification of triggered devices in a multiple use scenario.

This can be manually reset either by interrupting the power supply or by switching the unit to "Check" mode, (please 

note removal of cover will initiate tamper alarm).

Tamper function

This function is for detecting tampering or intentional removal of the cover. It detects the removal of the cover from the sensor 

unit and outputs an alarm.

It  is  reset  if  the  cover  is  returned  to  its  original  position,  but  check  the  operation  of  the  sensor  immediately  if  this  situation 

For precise operation, use EG-2000 (sold separately), and perform the following operation and sensitivity checks.

* Follow the EG-2000 instruction manual when performing these checks.

While checking that the sensor environmental LED lights ON, check the range of 

the coverage and the optimal sensitivity.

Set the internal output switch of the EG-2000 to L for use.

Supply  power  to  the  sensor  with  its  cover  removed,  and  select  "Check"  mode 

with the mode switch.

Refer to 7. Operation description.

First, begin activation by pressing the EG-2000 Send Button 

near the sensor. Ensure that both the alarm LED (Red) and 

the environmental LED (Orange) of the sensor are lit.

From the surface of protected window, point the wave transmission part of the 

EG-2000 at the sensor. Operate the equipment and check the sensitivity. Check 

the sensitivity of the sensor at all positions at the surface of protected window.
Note:  Some  positions  where  light  is  reflected  from  ceilings,  walls,  and  floors 

make  detection  difficult  for  the  EG-2000.  Shift  the  position  of  the  unit 

slightly to the left or right. If only the environmental LED of sensor lights 

ON, the sensor sensitivity is normal. 

Operate the sensor from the furthest point of required protection. Sensitivity is 

correct  when  just  the  environmental  LED  lights.  If  neither  alarm  LED  or 

environmental  LED  light,  then  sensitivity  is  too  low.  If  the  alarm  LED  also 

lights,  sensitivity  is  too  high.  If  sensitivity  is  not  optimal  in  certain  locations, 

check the coverage again or adjust the sensor sensitivity by the sensitity volume.

If there is a possibility of sound or noise within 

the  same  room,  whether  within  or  outside  the 

coverage, make some sound or noise and check 

to make sure that the Environmental LED does 

not light up. If it lights up from some sound or 

noise,  change  the  install  position,  or  increase 

the  number  of  sensors,  giving  them  each  a 

smaller range of coverage and lower sensitivity.  

After  checking  the  sensitivity,  set  the  mode 

switch  to  operation  mode,  and  then  replace 

the cover and tighten the cover lock screws. 

Set  the  sensor  mode 

switch to Operation mode, 

and check the operation of 

the alarm. 

From  within  the  coverage 

of  the  sensor,  point  the 

wave transmission  part  of  

the  EG-2000 at the sensor, 

and  operate  by  pressing 

the  send  button.  If  the 

sensor  alarm  LED  is  lit, 

the operation of the sensor 

alarm is correct.

Check  the  operation  of  the  installed  sensor. 

Use  for  daily  sensor  operation  checks  and 

during inspection ONLY.

Set the internal output switch of the EG-2000 

to H for use.

Note:  1) A  glass  jar/bottle  containing  metal 

coins can be used as a substitute for 

the EG-2000.

Using  7  or  more  coins  in  a  strong 

sealed  glass  container,  the  shaking 

of which replicates the EG-2000.

2) This is an alternative method of testing

unit sensitivity and operational in the 

absence of the correct equipment.

3) Obvious  special  care  is  needed  if 

this  method  is  used  as  shaking  to 

vigorously  may  result  in  the  glass 

breaking and personal injury.

Sensitivity check

Alarm operation check

Retrigger 47min.

Sensitivity is correct

Sensitivity is too high

Lower the sensitivity

Environmental LED: OFF

Alarm LED: OFF

Environmental LED: ON

Alarm LED: OFF

Environmental LED: ON

Alarm LED: ON

Sensitivity is too low

Increase the sensitivity

Mode switch

Check 

mode

Operation 

mode

Environmental LED

Alarm LED

Environmental LED

Alarm LED

Environmental LED

Alarm LED

Alarm LED

Coverage

EG-2000