Display function

:(beyond received light level)

Displacement indication function

Absolute value indication

supporting high resolution

Enhanced teaching features (sensitivity setting) 

Full auto teaching

Simply pressing the button allows easy teaching of an
object moving at a high speed.
The teach hold feature allows indication of the
maximum and minimum data.

Auto teaching

2-point teaching with and without the presence of work,
allows the detection of slight level differences such as the
thickness of a piece of work and/or the presence of a film.

Positioning teaching

This feature is ideal for high-accuracy positioning that
requires accurate determination of a detecting point.

Maximum sensitivity setting

For applications requiring a “maximum” sensitivity setting
such as the detection of work with a through-beam type-
fiber optic cable. The incorporated extra powerful light
would allow use in an adverse environment.

Manual setting

Arbitrary manual increase and decrease of a set-point
level allows level setting while checking the operation.

Auto sensing function compensates for adverse environment

The level of received light is constantly monitored and
fluctuation is detected and automatically adjusts the
activation/deactivation level.
Stable detection at optimum sensitivity is ensured even if
the received light level frequently fluctuates due to dust or
water drops.

Manual hysteresis setting feature

The hysteresis can be arbitrarily set according to the
application, allowing setting of a small hysteresis for
severe, high-accuracy detection and a large hysteresis for
detection of large variation and prevention of chattering.

Timer functions

On-delay, off-delay and on-off delay timer functions are
provided, which allows for a wide range of detecting and
input conditions from the connected devices.
The delay time setting is variable between:
10 ms, 20 ms, 40 ms, 60 ms, 80 ms, 100 ms and 120 ms.

Teach hold function

The sensor has the ability to hold instantaneous data for an
object moving at a high rate of speed during full auto teaching.
This data is displayed when the teaching has been completed.

All amplifiers should show “0” with no work.

Failure such as light
intensity degradation
possible if a negative
value is shown.

Possible failure

Received light level indication going beyond the

If the received light level at light blocking
is 10 and the level at light reception is
6000, the light blocking / light reception
ratio is calculated as 600 times.

8

7

6

5

4

3

2

1

9999

1024

Resolution of 1024

Position on
electronic volume

Detecting distance

Full range shown in values
between 0 and 9999

Level

The value for a deviation (positive or negative) of
received light level from the original level is shown at
the time of detection, which allows central
management of sensors.

H

3 2 5

L

1 2 0

(Data for light reception is 325 and for light blocking 120.)

11

Fiber

o

ptic

sensors

Содержание F71R

Страница 1: ...general purpose type NPN output F70AR F70AG F70AB F70AW PNP output F70ARPN F70AGPN F70ABPN F70AWPN Light source Red LED Green LED Blue LED White LED Output mode Open collector NPN PNP Model press pre...

Страница 2: ...ctronic volume 8 The level of received light is indicated in 4 digit number Min 0 Max 1023 The example above shows that the current receive light level is 123 with reference to the activation level Le...

Страница 3: ...l in high resolution provides highly accurate detection Wide dynamic range and high resolution are achieved at the same time High resolution is maintained even with a wide dynamic range The provided e...

Страница 4: ...fluctuates due to dust or water drops Manual hysteresis setting feature The hysteresis can be arbitrarily set according to the application allowing setting of a small hysteresis for severe high accur...

Страница 5: ...tion indicator is provided High speed response of 30 s H type sensor Variation Manual high performance model High accuracy 8 turn adjustment is equipped with a position indicator which allows direct r...

Страница 6: ...light level Detection output Stability output Stability indicator Flashes Easy to understand stability function When four consecutive detections with a received light level of 120 or lower of the act...

Страница 7: ...th straight M8 connector and 2 m cord Model FBC 4R2L equipped with angled M8 connector and 2 m cord Model FA7EU AC BF2 Description DIN rail mounting stopper Amplifier unit mounting bracket End unit Op...

Страница 8: ...5 RH non condensing IP40 10 55 Hz 1 5 mm amplitude 2 hours each in 3 direction 500 m s2 3 times each in 3 directions Environment Environmental Specification Specification Light source wavelength Indic...

Отзывы: