Page 2.8
T
T
a
a
m
m
p
p
H
H
e
e
a
a
d
d
D
D
w
w
e
e
l
l
l
l
T
T
i
i
m
m
e
e
Adjusting Dwell Time:
1.
Turn the labeler off; unplug the power cord from power source.
2.
Remove the electric cover by removing the screws.
3.
Locate the potentiometer (A & B) located on the electrical board. Potentiometer (A)
determines the time for the tamp head to advance out, (B) determines the time for the
tamp head to return back.
4.
Clockwise makes the time longer; counter clockwise makes the time shorter.
5
5
.
.
If you need more time than it will adjust see page 2.9.