Manual No.TDR-MNL-C202-A0-1-EN-100 

3  Installation and connection 

3.1  Installation into a host device 

5

 

TAKAYA RFID TR3 Series 

 

3

 

Installation and connection 

 
 

3.1

 

Installation into a host device

 

 

3.1.1

 

Installation from the Front 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.1.2

 

Installation from the Back 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Host Device 

M3 Screw 

Four, M3 holes 

Four, M3 holes 

M3 Screw 

Screw hole depth : 3mm 

Host Device 

Содержание TR3-C202-A0-1

Страница 1: ...User s Manual TR3 C202 A0 1 Manual No TDR MNL C202 A0 1 EN 100...

Страница 2: ...100 TAKAYA RFID TR3 Series Introduction Thank you for purchasing a TR3 C202 A0 1 RFID READER WRITER Be sure to read this manual before using the product After reading it store the manual in a conveni...

Страница 3: ...essly approved by the party responsible for compliance could void the user s authority to operate the equipment The following sentence has to be displayed on the outside of the device in which the tra...

Страница 4: ...s RFID antennas from implanted cardiac pacemakers or other medical devices please 22cm apart We recommend that you paste RFID sticker at equipment Be sure to observe the following precautions to ensur...

Страница 5: ...om the Front 5 3 1 2 Installation from the Back 5 3 2 Antenna installation into a host device 6 3 2 1 Screw holes 6 3 2 2 Guide 6 3 3 Connection 7 3 3 1 Attaching the Cable and Antenna 7 3 3 2 Direct...

Страница 6: ...capabilities Conform to international standards ISO IEC15693 and ISO IEC18000 3 Mode1 is supports Rich Products Various interface RS 232C USB TCP IP Antennas of various sizes Software TR3 series comm...

Страница 7: ...ies 2 Names of Parts and Functions 2 1 TR3 C202 A0 1 No Name Description CN1 This connector is for connection to the host FCC ID stickers Production numbers will be 8 digit serial number LED1 Displays...

Страница 8: ...and Functions 2 2 Antenna 3 TAKAYA RFID TR3 Series 2 2 Antenna 2 2 1 TR3 A202 No Name Description CN1 Connect the antenna cable Nameplate Production numbers will be 8 digit serial number Inspection m...

Страница 9: ...cription Inspection mark Screw holes M3 holes Nameplate Production numbers will be 8 digit serial number CN1 Connect the antenna cable 2 2 3 TR3 A401 No Name Description CN1 Connect the antenna cable...

Страница 10: ...lation into a host device 5 TAKAYA RFID TR3 Series 3 Installation and connection 3 1 Installation into a host device 3 1 1 Installation from the Front 3 1 2 Installation from the Back Host Device M3 S...

Страница 11: ...ection 3 2 Antenna installation into a host device 6 TAKAYA RFID TR3 Series 3 2 Antenna installation into a host device 3 2 1 Screw holes 3 2 2 Guide TR3 A401 is recommended that you set up a guide on...

Страница 12: ...na and antenna cables This product connects with Host Device that direct connection or connect using our interface 3 3 1 Attaching the Cable and Antenna 3 3 2 Direct connection to the Host Device Inte...

Страница 13: ...connection 3 3 Connection 8 TAKAYA RFID TR3 Series Host Device 3 3 3 Using the interface board to connect to the Host Device Interface Interface board please contact us TR3 C202 A0 1 Interface Cable I...

Страница 14: ...W 20 Ta 25 VCC 5 0V Standards ISO IEC 15693 ISO IEC18000 3 Mode1 Tags Tag it HF I my d I CODE SLI MB89R118 1 Data rate Speed Data rate 1 4 26 48kbps Reader Writer Tag 1 256 1 65kbps Tag Reader Writer...

Страница 15: ...CN1 Connector JST S10B PH SM4 TB LF SN Housing JST PHR 10 Contact JST SPH 002T P0 5S Pin assignment Pin No Symbol Function 1 VCC Power 2 VCC Power 3 GND GND 4 GND GND 5 Rx Received data signal 6 Tx Tr...

Страница 16: ...data Installation M3 Screw Screw is not included Electrical data Power Supply Voltage 5V 10 Current consumption approx 120mA Carrier off approx 35mA Power down mode approx 24mA Consumption max 1 0W Te...

Страница 17: ...Manual No TDR MNL C202 A0 1 EN 100 4 Specifications 4 1 TR3 C202 A0 1 12 TAKAYA RFID TR3 Series Dimensions Unit mm Tolerance 0 3mm is Recommended Dimension Screw hole depth 3mm...

Страница 18: ...IF N1 TCP IP interface Interface board TR3 IF U1 USB interface Electrical Characteristics CN1 Item Condition MIN TYP MAX Unit H input voltage RX IO1 IO2 IO3 2 5 5 0 V L input voltage RX IO1 IO2 IO3 0...

Страница 19: ...1 Connector JST S2B PH SM4 TB LF SN Housing JST PHR 2 Contact JST SPH 002T P0 5S Pin assignment Pin No Symbol Function 1 RF Analog signal 2 GND GND Dimensions W x D x H 60 x 65 x 9 1 mm Weight approx...

Страница 20: ...ctor JST S2B PH SM4 TB LF SN Housing JST PHR 2 Contact JST SPH 002T P0 5S Pin assignment Pin No Symbol Function 1 RF Analog signal 2 GND GND Dimensions W x D x H 15 x 52 5 x 9 1 mm Weight approx 3g Me...

Страница 21: ...nector JST S2B PH K S LF SN Housing JST PHR 2 Contact JST SPH 002T P0 5S Pin assignment Pin No Symbol Function 1 RF Analog signal 2 GND GND Dimensions W x D x H 15 x 30 x 9 1 mm Weight approx 2g Mecha...

Страница 22: ...Cable loss 9cm approx 0 061dB 50cm approx 0 337dB Dimensions 4 3 2 TR3 AC 2A Model Name Specifications Item Parameter RoHS EU RoHS 2002 95 EC Support Linetype Coaxial cable 1 5D 2V Connector PH PH Ca...

Страница 23: ...f insulation by moisture or dust Connector corrosion by corrosive gases In order to use this product at its best please conduct routine or periodic inspections Item Maintenance Criteria Temperature Te...

Страница 24: ...Manual No TDR MNL C202 A0 1 EN 100 19 TAKAYA RFID TR3 Series Revision History Revision code Date Revised contents 1 00 2010 10 28 Original production...

Страница 25: ...20 URL http www takaya co jp Mail rfid takaya co jp...