Useful Function
49
The approximate time of high speed, medium speed, and low speed is as follows:
- CV High Speed: Approx. 10 msec - CC High Speed: Approx. 10 msec
- CV Medium Speed: Approx. 100 msec - CC Medium Speed: Approx. 100 msec
- CV Low Speed: Approx. 200 msec - CC Low Speed: Approx. 200 msec
The approximate time of high speed, medium speed, and low speed is as follows:
- CV High Speed: Approx. 100 msec - CC High Speed: Approx. 10 msec
- CV Medium Speed: Approx. 300 msec - CC Medium Speed: Approx. 100 msec
- CV Low Speed: Approx. 500 msec - CC Low Speed: Approx. 200 msec
Setting contents will be confirmed when the FUNC. key is pressed.
Any change of setting item without pressing the FUNC. key is not set.
Startup Mode Selection
* This function can be set for full-featured type "model name with F" only.
Allows you to select the optimal output startup properties for each use.
1. Constant Voltage (CV) Priority Mode (High/Medium/Low speed)
Perfect when using as a normal constant voltage power supply for testing equipment and devices.
2. Constant Current (CC) Priority Mode (High/Medium/Low speed)
Perfect when wishing to control the current of the load such as electromagnets etc. or when wishing to include the
constant current pulse to nonlinear loads such as diodes etc.
Setting Procedures
Press the Function “FUNC.” key.
The FUNC. lamp will light.
The Setting Item Number will be displayed in the Number Display
(voltage) and the parameter will be displayed in the Number
Display (current).
Select Item number 1 with the VOLTAGE dial.
Select 0 to 6 with the CURRENT dial.
Set Value 0 = Constant Voltage (CV) Priority High Speed Mode
Set Value 1 = Constant Voltage (CV) Priority Medium Speed Mode
Set Value 2 = Constant Voltage (CV) Priority Low Speed Mode
Set Value 4 = Constant Current (CC) Priority High Speed Mode
Set Value 5 = Constant Current (CC) Priority Medium Speed Mode
Set Value 6 = Constant Current (CC) Priority Low Speed Mode
Press the FUNC. key again to set
Setting contents will be confirmed and the "Number Display"
returns to measurement display.
MEMO (30V/60V)
MEMO (500V/1000V)
MEMO
Содержание HX-S-G2 Series
Страница 165: ...Special Loads 165 This page is blank...
Страница 169: ...Maintenance 169 This page is blank...
Страница 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Страница 212: ...Specifications 212 2 HX S 030 400G2 F I...
Страница 213: ...Specifications 213 3 HX S 060 100G2 F I...
Страница 214: ...Specifications 214 4 HX S 060 200G2 F I...
Страница 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Страница 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Страница 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Страница 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Страница 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Страница 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Страница 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Страница 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Страница 223: ...Specifications 223...
Страница 239: ......