- 20 -
NORMAL OPERATION
•
Flow rate to activate the T-K3-OS/SP : 0.5 gallon per minute
•
Flow rate to keep the T-K3-OS/SP running : 0.4 gallon per minute
1. NORMAL OPERATION
WITHOUT REMOTE CONTROLLER
1.
Open a hot water tap.
2.
Mix cold water with the hot to get
the correct temperature water.
3.
Close the hot water tap.
2. NORMAL OPERATION
WITH REMOTE CONTROLLER: TK-RE02 (Optional)
1.
Press the operation ON/OFF button.
2.
Set temperature. (Example: 104
°
F)
The temperature options
(unit:
°
F)
99
100
102
104
106
108
110
111
113
115
117
122
131
140
158
167
•
Temperature settings 140
°
F and above are for heating applications only.
3.
Open a hot water tap.
Mix cold water with the hot if you need.
4.
Close the hot water tap.
WARNING
Hot Water temperatures over 125
°
F can cause severe burns
instantly or death from scalding.
•
The outlet hot water temperature of the FLASH T-K3-OS/SP
water heater is factory set at 122
°
F.
•
Feel the water temperature before bathing or showering.
The temperature is
displayed on the remote
controller when the remote
controller is ON.
Lamp is
ON
Lamp is
OFF