42 • On-Demand Water Heater Service Handbook for 240, 340 & 540 Condensing Models
9.2 Insert an air compressor’s air
hose into the opening from
which the burner was removed.
◦
Blow air up into the heat
exchanger to remove
soot and debris.
◦
At the same time,
vacuum the combustion
chamber with a shop vac.
◦
Continue until all dirt has
been removed.
10.
Clean the parts of the flame rod and
air/fuel ratio rod (AFR) that are on the
inside of the burner. (Use sand paper
or other appropriate abrasive.) See
“Cleaning the Rod Assembly (Flame
Sensor and Air/ Fuel Ratio Rod),”
NOTICE: Do not clean the metal
extensions on the outside of the
burner. See Figure 33.
11. Reassemble all items in reverse order.
WARNING!
Ensure that you reinstall
the brass-colored screw that
secures the gas valve to the gas inlet
connection. Failure to do so can lead
to a gas leak which can result in severe
personal injury or death.
Things to remember:
•
Reinstall the solenoid connectors
to the gas valve before you
reinstall the gas valve/manifold
plate assembly. See Figure 34.
•
Only four solenoid circuits have
numbers labeled on their wires: 3, 9,
53, and 73. (See Figure 34. See also
schematics on pages 30 or 31.)
•
The connector which connects to the
gas proportional valve is not labeled
with a number. It has two wires: red
and white. (See schematics on pages
NOTICE:
□
If necessary, refer to the
exploded assembly views
which start on page 71.
□
Inspect all gaskets.
□
Ensure that the black O-rings
and mesh filter on the gas
valve inlet are not pinched or
otherwise damaged during
reinstallation.
□
ALL screws must be hand
tightened only, especially
around the gas valve inlet.
□
Reconnect the plastic tube
that runs from the gas
valve to the bottom of the
combustion chamber.
□
Reinstall the fan.
□
Reinstall the igniter assembly.
□
Verify that all components are
reattached and are secure.
□
Ensure that all wire
connectors have been
reconnected.
Flame Rod /AFR
Assembly
Front of burner:
• Do not clean the extensions
on the outside (shown above).
• Clean the metal extensions on
the inside of the burner.
Figure 33.
Solenoid
(locations vary)
Connector
Numbered
Wire
Stamped
Number
In each case, these numbers
must match.
Connectors have no polarity.
Figure 34.
□
Ensure that the solenoid
connectors are reinstalled in
the correct locations.
To do so, match the printed
number on the wire to the
corresponding number that
is stamped on the solenoid
body.
For example, if “73“ is printed
on a wire, its pin should plug
into the side of the connector
that has the number “73”
stamped closest to it.
□
All connectors with
yellow
wire
go to the same circuit. They
may be reconnected in any
order.