Horizontal Installation Diagram (with direct-venting)
Wall
Sidewall vent
terminations
Backflow
preventer*
Vertical
condensation
drain**
See the picture below for
detailed connection instructions
to the Direct-vent conversion kit .
Vertical Installation Diagram (with direct-venting)
Fire Stop
Hanger
See the picture below for
detailed connection instructions
to the direct-vent conversion kit .
Roof
Rain cap
Backflow
preventer*
Vertical
condensation
drain**
Roof flashing
Roof flashing
* Backflow preventer (Recommended for freezing weather
conditions: 2 °C (36 °F) and below) .
** Vertical condensation drain must be installed in
accordance with local codes .
Horizontal Installation Diagram with Direct-Vent
Concentric Termination
Wall
Direct-vent concentric
termination
Installation Diagram of Direct-Vent Conversion Kit (TK-
TV10) with a water heater
Remove the air intake
cover plate to attach
the air intake port from
the Direct-vent
conversion kit . (TK-TV10)
Cover the louver of the water heater with the plate
provided in the Direct-vent conversion kit to complete the
conversion to sealed combustion .
Air intake cover plate
Storm collar