WATER HEATER
PROBLEM
POSSIBLE SOLUTIONS
Unit does not ignite when water
goes through the unit.
• Is the flow rate over 3.0 l/min? (p. 18)
• Check for the filter on cold water inlet. (p. 21)
• Check for reverse connection and cross connection.
• If you use the remote controller, is the power button turned on?
(p. 18,19)
The fan motor is still spinning after
operation has stopped.
• This is normal. After operation has stopped, the fan motor keeps
running for 15 to 75 seconds in order to re-ignite quickly, as well as
push all exhaust gas out of the flue.
REMOTE CONTROLLER (OPTIONAL)
PROBLEM
POSSIBLE SOLUTIONS
Remote controller does not display
anything when the power button is
turned on.
Press the ON/OFF button.
If the lamp does not light:
• Make sure the unit has power supply.
• Make sure the connection to the unit is correct.(p. 16)
An ERROR code is displayed.
Please see the p.24
Remote controller can not change
the set temperature.
Is priority lamp lit?
If it is not, press the priority button after closing all hot water taps.