39
Page
Normal Operation
Owner's Guide
How to change to the High temperature mode
1. Turn off power to the remote controller by pressing the
“ON/OFF”
button. (Lamp is OFF to indicate
that power is off.)
2. Press and hold both the
“HOT”
and
“COLD”
buttons simultaneously for at least 5 seconds, then
make sure that “1” (or “0”) is displayed on the remote controller.
I N
OUT
FLOW
L/M G/M
“1” is displayed for single unit.
I N
OUT
FLOW
L/M G/M
“0” is displayed for Easy-Link System.
3. Press the
“TIME”
button. Make sure that
“OFF”
and
“F1”
are displayed on remote controller.
I N
OUT
FLOW
L/M G/M
4. Press the
“INFO”
button. Afterward, make sure that
“OFF”
blinks.
I N
OUT
FLOW
L/M G/M
5. Press the
“HOT”
button or
“COLD”
button to set display to
“on”
. Make sure that
“on”
is blinking.
I N
OUT
FLOW
L/M G/M
6. Press both the
“BUZZER”
button and
“INFO”
button simultaneously to save the setting. Make sure that
the display is no longer blinking.
I N
OUT
FLOW
L/M G/M
7. Press the
“ON/OFF”
button to exit the edit mode.
8. Turn on power to the remote controller by pressing the
“ON/OFF”
button again. (Lamp is ON to indicate
that power is on.)
OTHER FEATURES OF THE REMOTE CONTROLLERS
-Features available on 100112183 (TK-RE02) and 100112155 (TM-RE30)-
<Buzzer operation>
If there is a problem with the water heater, the remote controller will sound a buzzer and display the error
code to inform you of the source of the problem.
You can stop the buzzer by pressing : "
any button"
for
100112183 (TK-RE02)
"Buzzer button"
for
100112155 (TM-RE30).
For details on the error code, refer to p. 43.
NOTE: If you want to disable the buzzer operation, press and hold the "BUZZER" button for 3 seconds or
longer. (100112155 (TM-RE30) only.)
Information mode>
You can get some information about the water heater condition by pressing :
"INFORMATION"
button for
100112183 (TK-RE02)
"INFO"
button for
100112155 (TM-RE30)
During the information mode, the information will be rotated by pressing the
"INFORMATION" or "INFO"
button as follows:
Inlet
water temperature
Outlet
water temperature
Water
flow
Finish
information mode