34
Description
TB9400/TN9275 Installation and Operation
© Tait International Limited May 2023
Offline Mode
Offline mode allows a maintenance engineer to carry out tasks that can not
be done while the base station is in service - such as activating firmware or
running diagnostic tests.
1.8.3
Intermodule Communications
A system control bus and a subrack interconnect board link the modules in
the subrack and carry alarm and control signaling between the reciter and
the other modules, as shown in
.
Specific configuration settings for dual base stations are described in
“Recommended Configuration Settings” on page 66
Figure 1.7
Intermodule communication paths
Fan
IC
2
RS-485
RS-485
I C
2
Fan
Fan
PA 1
m
P
Subrack Interconnect Board
Reciter 1
m
P
Front Panel
Fan 3:
PMU
Fan 1:
Reciter 1/
PA 1
Fan 2:
Reciter 2/
PA 2
User
Controls
PMU
m
P
I C Current
Source
2
RS-485
RS-485
Fan
PA 2
m
P
Reciter 2
m
P