74
Programmable I/O Lines
TM8000 3DK Hardware Developer’s Kit
Application Manual
September 2003
© Tait Electronics Ltd
3.2.8
Monitor Status
Application
This output signal is used to indicated the state of the monitor function.
This allows an external application to determine whether the user has
activated the monitor.
Note
This output line only indicates the monitor function and not the
hookswitch monitor function.
For more information on the monitor function refer to the user guide and
the online help of the programming application.
Configuration
Configure an output line and associate it with this action. Set the active state
to be high or low (as required).
Timing
The response time of this output line is less than 2 ms.
Description
When the radio detects a change in state of the monitor function, the radio
sets the state of this output line to reflect the state of the monitor function.
When monitor is active, the output line is active. When monitor is inactive
the output line is inactive.
Related Actions
The ‘
’ output signal indicates the state of the hookswitch.
3.2.9
Hookswitch Status
Application
This output signal is used to indicate the state of the hookswitch.
Configuration
Configure an output line and associate it with this action. Set the active state
to be high or low (as required).
Timing
The response time of this output line is less than 2 ms.
Description
When the radio detects a change in state of the hookswitch, the radio sets
the state of this output line to reflect the state of the hookswitch. When the
hookswitch is off the hook, the output line is active. When the hookswitch
is on the hook, the output line is inactive.
Related Actions
None.