24
Description of the Radio Interfaces
TM8000 3DK Hardware Developer’s Kit
Application Manual
September 2003
© Tait Electronics Ltd
3. For tap into the Rx path, nominal level refers to the level required to give output at RX_AUD that is same as the
60% dev level from the receiver. The level specified applies at 1kHz only.
4. AUD_TAP_IN uses a DC-coupled analog-to-digital converter and the bias voltage specified in
used to maximise dynamic range. The DC bias is removed internally by a digital high-pass filter so the Tx carrier
frequency will not be affected by any bias error. it is recommended to use external AC-coupling for applications
which do not require modulation to very low frequencies.
Table 2.8
Auxiliary connector - data characteristics
Parameter
Standard
Test method and conditions
Comments
min.
typ.
max.
units
Serial port
Baud rate:
1200, 2400, 4800,
9600, 14400, 19200
bit/s
All UART parameters are fixed
and common to all UARTs
except for the baud rate
which is configurable and
different for different modes/
applications
Data bits:
8
Start bit:
1
Stop bit:
1
Parity:
None
Protocol:
CCDI2
Flow control:
Software
XON/XOFF
GPIO
Delays:
I/O mirror to IOP
UI key delay
500
50
!
s
ms
Table 2.9
RSSI voltage vs. signal strength