32
Base Station Specifications
TB9300 Specifications Manual
© Tait International Limited August 2022
Mismatch capability
Ruggedness
Stability
open and short circuit load at any phase angle for one
hour
5:1 load VSWR at all phase angles
d. Under power foldback.
Protection
Temperature
Current
Supply voltage
VSWR
power foldback to 10% if RF power devices exceed
safe operating conditions
power foldback and shutdown if RF power devices
exceed safe operating currents
power foldback to 10% when supply voltage is 24 V to
26 V and 30 V to 32 V; shutdown when supply voltage
is < 24 V and > 32 V
power foldback to 10% at VSWR extremes;
continuous analog power foldback to maintain 100%
duty cycle into mismatched loads
Adjacent channel power
All modulation types
Steady state
Transient
<–60 dBc (EN 300 113 & EN 300 086)
<–50 dBc (EN 300 113)
Modulation fidelity
<2%
Intermodulation
–40dBc with interfering signal at –30dBc at TB9300
base station RF output. For Europe, 70dB ratio is
achieved using an external Circulator/Isolator with a
minimum isolation of 30dB and less than 0.5dB
insertion loss.
Sideband noise
± 2.5 kHz
± 100 kHz
≥
± 1.5 MHz
< –120 dBc/Hz
< –145 dBc/Hz
< –154 dBc/Hz at 50 W
< –157 dBc/Hz at 100 W
e. No modulation, measured from center frequency.
Radiated spurious emissions
Transmit - B and C bands
Transmit - G and H bands
Transmit - K and L2 band
Standby
< –36 dBm 30 MHz to 1 GHz
< –30 dBm 1 GHz to 4 GHz
< –36 dBm 30 MHz to 1 GHz
< –30 dBm 1 GHz to 4 GHz
< –30 dBm 1 GHz to 12.75 GHz
<–20 dBm to 9 GHz
<–57 dBm to 1 GHz
<–47 dBm 1 GHz to 4 GHz
General (Continued)