TN-1114-AN
Page 7 of 10
© Tait Electronics Limited 21 December 2005
6
Configuring the Base Station
Extended bypass is configured in the channel profile assigned to the
operating channel. If a different operating channel is selected, the signal
path configured for that channel will take effect.
Important
Selecting this function bypasses the limiter. This may allow
overdeviation and cause the equipment to become non-
compliant. It should be selected only when the TB8100 is
connected to approved level-controlled devices (modems,
trunking controllers, etc.).
Important
With extended bypass you cannot use the balanced line or
internal talk-through repeater connections from receiver to
transmitter.
To configure the signal path for extended bypass.
1.
Run the Service Kit and open the Add or Edit Channel Profile dia-
logue box for the appropriate profile.
2.
Select the Signal Path tab.
3.
Select the
Bypass
check boxes for Path B (both transmit and receive).
Extended bypass
check boxes appear alongside the
Bypass
check
boxes.