MBZ-00001-01
General Information
9
Copyright © 2004 Tait Electronics Ltd
November 2004
Warning:
Exceeding the deratings shown in Section 3.9 (Power Supply Cooling and
Derating) will cause the equipment to overheat.
Output Over-voltage Protection
… 18 to 21V
DC
Type: Shutdown
Reset: Power OFF and ON
Output Hum and Noise
… <40m V
pp
(25A load with 230V
AC
sup-
ply)
Overload Current Limit
… 37 to 48A
Type: Constant current limiting
(voltage foldback)
Reset: Auto recovery
DC Output Connector
… Phoenix Contact Feed-through
terminal block (refer to Section 3.3.1)
1.2.5
Miscellaneous
Remote Control (Auxiliary RC and –RC)
Power OFF
… 4 to 10V RC and –RC
Power ON
… 0 to 0.8V RC and –RC
Note:
The remote control circuit is optically isolated from the rest of the power
supply.
Remote Sense (Auxiliary S and –S)
… 0.3V maximum voltage drop between
sense inputs and load terminals