Taik T210A Скачать руководство пользователя страница 11

5

Specifications

:

5.1

 

S

pecifications

Analog

 

input:

DC 4

-

20mA

Input range

±0

.

05

F.S. ±2 digit

Deviation range

Display

 

screen

Format

LCD white backlit

5

 

digits

Instantaneous flow digits

10

 

digits

Integrated flow digits

Relay contact status, RS

-

485 communication status

Pulse output,Analog output percentage
Input signal status, Unit display, Error message

Status symbol

Analog output:

Output range

DC4

-

20mA

 

isolated

Corresponding value

Instantaneous flow

Maximum load

350

Ω

Deviation

 

range

±

0

.

1

%

R

.

O

.

Communication

Interface

RS485

Protocol

MODBUS , RTU format

Baud

 

rate

2

4

00 ~ 1

92

00 

programmable

Address

1 ~ 1

99

 

programmable

Data

 

formal

N,8,1

/

N,8,2 O,8,1 E,8,1

/

/

Parallel

 

connection

32

 

meters

 

programmable

Pulse

 

output

:

Output

 

genre

Open Collector 

(

O.C.

)

Corresponding value

Integrated flow

Setting range

0

.

001

-

999999

Pulse

 

width

0

.

001

-

9

.

999

 

sec.

Relay contacts output:

Output

 

genre

A contact (N.O.)

Corresponding value

Instantaneous flow high/low alarm or error alarm

Setting range

0

-

999999

Contact load

AC240V

 

5A

DC24V

  

5A

Maximum load

DC30V

 

30mA

Auxiliary

 

power

 

supply

Output voltage

DC5V, DC12V, DC24V

(

option

)

Max. current

30mA

Power

 

supply

Auxiliary

 

power

 

supply

AC

/

DC85

-

265V

Frequency

 

Range

45

-

70Hz

Power

 

consumption

15VA

(

All modules

)

Permissible module quantity

At most 4 sets

DC analog output module

2 sets

(

B

C

)

Rs485 

module quantity

1 set

(

A

)

Pulse and relay contacts module

1 set

(

D

)

Содержание T210A

Страница 1: ...T210A Instruction Manual 07 2020 TAIK Senflow T210A OK PROG...

Страница 2: ...ay 5 push buttons If setting first analog output will display If setting second analog output will display If setting second relay contact will display Relay contact activated If setting pulse output...

Страница 3: ...Cut out Unit mm Cut out size Side view 96 96 2 Connection Diagrams 2 N L 24V COM 5V 12V A Ext C IN B C D Aux Source Analog Input Rear view Meter connection Module A B O RS 485 RS 485 1 1 Analog outpu...

Страница 4: ...low Ao1 Output display Ao2 Output display Non resettable integrated flow Instantaneous flow AO2 AO1 PROG Keys Operation Advanced to the previous display Advanced to the next display Clear integrated v...

Страница 5: ...GAL 1kg 2 205Lb 0 001TON 1day 24hour 1440min 86400s ERR10 NOINIT Ex factory without calibration ERR1 OVERFD Instantaneous flow exceed set value ERR2 OVER P Pulse output exceed available output range E...

Страница 6: ...3 S d H M Integrated flow units AO1 Ao1 Output option Instantaneous flow power decimal point 0000 0000 AO1 Ao1 4mA Corresponding value AO1 Ao1 20mA Corresponding value AO2 Ao2 Output option AO2 AO2 Ao...

Страница 7: ...sponding options L M3 P Pulse corresponding value decimal point position 00 0 0 0 1 P Pulse corresponding value 000000 999999 Set to PuLse R2 Relay activation value R2 Relay activation set point R2 Ou...

Страница 8: ...nge 000000 999999 Square root of input value OFF ON Set up for average sampling times Range 00 99 00 means 10 times LCD backlight set up LCD backlight ON LCD backlight stays on dEFuLT LCD backlight sh...

Страница 9: ...rresponding value Range 000000 999999 Ao1 20mA corresponding value Range 000000 999999 Ao1 OFF No output FLOW flow output corresponding value Ao2 4mA corresponding value Range 000000 999999 Ao2 20mA c...

Страница 10: ...ange hysteresis setting 0000 9999 RS 485 p N 8 1 O 8 1 E 8 1 N 8 2 arity setting RS 485 communication address set up Range 001 199 R2 activation set up point more than or equal to set value less than...

Страница 11: ...Address 1 199 programmable Data formal N 8 1 N 8 2 O 8 1 E 8 1 Parallel connection 32 meters programmable Pulse output Output genre Open Collector O C Corresponding value Integrated flow Setting rang...

Страница 12: ...e immunity Conducted emission EN 55011 Radiated emmission EN 55011 Harmonic current emissions EN 61000 3 2 Voltage changes voltage fluctuations and flicker En 61000 3 3 Electrostatic discharge IEC6100...

Страница 13: ...Address Hi Start Address Lo Number of Word Hi Number of Word Lo Error Check End of Frame 01H FFH 03H 0 nnH 0 nnH 0H 1 nnH CRC Lo CRC Hi 1 Byte 1 Byte 2Byte 2 Byte 2 Byte Response Command is correct S...

Страница 14: ...0xc0 0x80 0x41 0x00 0xc1 0x81 0x40 0x01 0xc0 0x80 0x41 0x01 0xc0 0x80 0x41 0x00 0xc1 0x81 0x40 0x00 0xc1 0x81 0x40 0x01 0xc0 0x80 0x41 0x01 0xc0 0x80 0x41 0x00 0xc1 0x81 0x40 0x01 0xc0 0x80 0x41 0x00...

Страница 15: ...byte R R W 0022 0016H Correction factor High byte 0026 001AH 0025 0019H 0024 0018H Density High byte 0023 0017H Density Low byte Average value set up 0031 001FH 0030 001EH 0029 001DH 0028 001CH 0027...

Страница 16: ...i D 2 48 C 2 32 B 2 16 A 5 4 3 2 10 9 8 7 6 Decimal position 0 No decimals 1 First decimal place 2 Second decimal place 3 Third 4 Fourth decimal place decimal places Flow units 0 ml 1 L 2 m 3 Gallon 4...

Отзывы: