![Taiji TSK-110A Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/taiji/tsk-110a/tsk-110a_operating-instructions-manual_3264339015.webp)
-13-
<TSK-130A, 230A>
1.
Daily maintenance (cleaning of sake passage)
(1) Remove the used Cubitaner in the following procedure:
• Leave the power switch turned ON.
1) Turn the knob of the valve A to the left and adjust it to the “SHUT” position. Throw the nozzle (sake outlet)
down to drain the sake remaining inside. For the TSK-230A, it is necessary to throw both nozzles down to
drain sake.
2) After the nozzle has been thrown down, remove the joint part between the valve A and the joint hose.
For a machine that has no sake meter, the inner sake cannot be drained unless this work is finished first.
3) When the inner sake has been drained out, return the nozzle and remove the Cubitaner from the main
body.
4) Remove the valve A from the Cubitaner.
(2) Put about 2 liters of water (70°C or below) in a Cubitaner intended for cleaning (an empty Cubitaner).
After mounting the valve A, set it on the main body and connect the valve A to the joint hose.
• Never use any detergent.
(3) Provide for a container for cleaning somewhat large. Turn the knob of the valve A to the right and adjust it to
the “OPEN” position. Throw the nozzle down or press the “manual switch.”
(4) Water comes out of the nozzle and the pipe inside is cleaned.
(5) After cleaning, remove the Cubitaner for cleaning in the procedure of (1) above and press the “power switch” to
turn off the machine.
• The drained sake should be used for cooking and so on. After cleaning, however, some water drops may
remain inside. When you dispense sake next time, drain some at the beginning and then use the
dispensed sake.
2.
You should fix the sake meter diligently.
Remove the sake meter from the main body and then the cap off the upper part of the sake meter. Using an
accessory cleaning brush, clean inside of the pipe.
3.
Water in the water bath tank should be replaced once a month.
At that time, turn off the power switch without fail and open the water drain valve to drain water.
4.
Use soft cloth when you take care of the main body. Use a neutral detergent intended for cleaning cups and
dishes, and soak the cloth in a solution of this detergent. Wipe off contamination in such a manner that you
clean furniture.
This machine is partly made of resin. Do not use any volatile liquid like thinner or any alkaline detergent.
5.
Fix the nozzle at least twice a month. (Fig. 15)
Put a tooth brush in water and use it to wipe off
contamination from the sensor electrode located at the
nozzle tip.
6.
Maintenance for server bottle holder and tray
Remove the server bottle holder from the main body and
pull out the tray from the server bottle holder.
Neatly wash them with warm water.