![Taiden VIDEO SERIES Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/taiden/video-series/video-series_installation-and-operating-manual_3243041009.webp)
3
1.3 Protocol and address code setup
Control protocol, baud rate and camera address code
should be configured before installation. There are two
switches on PCB.
1.3.1 Switch for protocol and baud rate
Setup protocol and baud rate
Switch for camera type
Switch for NTSC/PAL
1.3.2 Setup address code
Address code of the camera should be configured
before using. Address code (ID) can be setup through
ten-digital dial switch on PCB which uses binary 8421
code. Maximum encoded address is 255, switch ON
stands for 1, OFF for 0.
Setup address code
№
1
2
3
4 5 6 7 8
Address
code
1
2
4
8 16 32 64
128
The definition of address code is listed in above table:
switch
№
1 stands for route 1, switch
№
2 for route 2,
switch
№
3 for route 4, etc. To set required route
№
,
just switch corresponding switch to ON. If the required
route number can not be represented by one switch,
just sum up needed switches.
For example: for route 1, switch
№
1 to ON.
Another example: for route 37, switch
№
1, 3, 6 (stands
for 1, 4 and 32 respectively) to ON.
Switch status
PRO0
(Pin1)
PRO1
(Pin2)
PRO2
(Pin3)
Protocol/Baud rate
ON ON ON KN, 9600
Switch status
ZM0
(Pin4)
ZM1
(Pin5)
Camera
OFF OFF SONY
ON OFF SANYO
OFF ON
CNB
ON ON
LG
Switch status
NT/PAL(Pin6)
Camera
standard
OFF NTSC
ON PAL
Note:
)
Factory default protocol is KN, baud rate is
9600, camera type is SONY, camera
standard is PAL, need not modify.
)
Factory default address code is 1;
)
Please make sure that dial switch is in correct
place, otherwise the camera may be out of
control;
)
Please confirm that you can control the
camera before installation.