(14) "DEL" relay delay action time setting option, if the protection parameter has
been set, when the instrument detects that the real-time data exceeds the set
parameter for less than the relay action delay time, the relay does not open; if the
instrument detection data exceeds the setting The time of the parameter is greater
than the delay time of the relay, and the relay is disconnected. The parameters are
set in the same way as "NCP".
PIC.(8-11)
(15) "FCH" communication address setting function, this function can change the
default communication address of the display and detection module, and set the
parameters in the same way as "NCP".
PIC.(8-12)
(16) "SNR" screen current value setting option, if the setting value of this option is
not 0, and the information screen time value is not 0, then when the actual current
value is less than the SNR setting value, the display device The display will be turned
off after the set real time is reached. When the actual current value is detected to be
greater than the set SNR value, the LCD will automatically light up. The parameters
are set in the same way as "NCP".