Taidacent VAC8010F Скачать руководство пользователя страница 1

www.banggood.com

1

Manual

1.

Instrument introduction

VAC8010F is a multi-function meter based on 2.4 wireless data transmission
technology. It can display various physical parameters such as voltage, current, power,
capacity, energy, temperature and running time in real time. The battery can be
realized separately through two reserved relay interfaces. Charge and discharge
management and overvoltage, undervoltage, overcurrent protection. Moreover, the
meter uses a 2.4-inch color liquid crystal as a display, and the display data is more
comprehensive, clear, and easy to observe.

2. Instrument characteristics:

1. Wirelessly transmit data to avoid interference caused by complicated wiring
between the display and the detection module, and the wiring is more convenient.
2. Hall sensor is used to realize non-contact detection current, without disconnecting
the wire, safe, reliable and convenient.
3. Voltage, current, power, temperature, capacity, percentage of remaining capacity,
and running time are displayed simultaneously.
4. Dual relay interface, can manage charging and discharging separately.
5. With charging overvoltage, discharge undervoltage, charging overcurrent,
discharge overcurrent protection.
6. With power-off memory function, you can record the AH number and WH
number before power-off.

3. Technical indicators

Item

Specification

Input

voltage

Measuring range when

self-powered

6V~80V

Measuring range when

externally powered

0~120V

Input current measurement range

0~100A

Содержание VAC8010F

Страница 1: ...avoid interference caused by complicated wiring between the display and the detection module and the wiring is more convenient 2 Hall sensor is used to realize non contact detection current without d...

Страница 2: ...1 100 Accuracy Voltage 1 2 Current 2 5 Temperature 1 5 Measurement rate 5 times sec Relay delay time 0 60 S Communication distance Open single group 10 meters Protection type and setting range OVP ov...

Страница 3: ...gy A Percentage of remaining battery capacity 4 The time required for the battery to be fully charged or discharged calculated based on charge and discharge current and capacity B Power value 5 Wirele...

Страница 4: ...and then connect it The positive and negative poles of the battery power supply are connected to the voltage measurement port Bat note that is connected to the positive pole of the battery power supp...

Страница 5: ...pply wiring mode can be used First adjust the jumper cap of the power supply selection interface to 3W and the external power supply Connect the positive and negative poles to Vext pay attention to to...

Страница 6: ...onnect the positive pole of the battery power supply to the positive pole of the load The negative pole of the battery power supply is connected to the negative pole of the load through the Hall senso...

Страница 7: ...s the relay should be provided Connect the control port of the relay to the interface of the charging controller If you want to control the positive pole of the charging pass the positive line through...

Страница 8: ...tage as the relay should be provided Connect the control port of the relay to the discharge controller interface If you want to control the positive pole of the discharge pass the positive line throug...

Страница 9: ...it will prompt the nature and range of the set parameters then click the up or down button to change the size of the set parameter value Note The current display line will be set when the parameter i...

Страница 10: ...ton to enter the parameter setting interface of the figure 8 3 The parameters are set in the same way as NCP PIC 8 3 4 LVP discharge undervoltage protection value If the value is greater than 0 the pr...

Страница 11: ...s option click OK button to select the option click the up button to lock the button as shown in Figure 8 5 After the button is locked the button will not work only long Press OK button 10S or more to...

Страница 12: ...wn in Figure 8 7 PIC 8 7 9 CER current return function If the actual current value is zero and the instrument display value is not zero move the cursor to this option and press OK to zero the current...

Страница 13: ...s the button to turn on or switch charging and discharging as shown in Figure 8 9 PIC 8 9 13 SFH search device function this function can realize one to many communication By modifying the parameters...

Страница 14: ...8 11 15 FCH communication address setting function this function can change the default communication address of the display and detection module and set the parameters in the same way as NCP PIC 8 1...

Страница 15: ...of SNR is used to implement the interest screen function The parameters are set in the same way as NCP PIC 8 14 17 RFS color reversal function If this function is enabled the displayed color will be c...

Страница 16: ...aged 2 The positive and negative poles cannot be reversed and the reverse may damage the instrument 3 The working temperature is 10 50 C the storage temperature is 20 70 C and the instrument should be...

Отзывы: