background image

1

T

S50

00

 

(51.2V

 

100Ah)

 

Lithium

 

Iron

 

Phosphate

 

Battery

 

User

 

Manual

Содержание TS5000

Страница 1: ...1 TS5000 51 2V 100Ah Lithium Iron Phosphate Battery User Manual...

Страница 2: ...nitions 6 5 LiFePO4 Battery Safety Operating Guidelines 9 5 1 Application Schematic 9 5 2 Tools 9 5 3 Security equipment 9 6 Installation 10 6 1 Installation location 10 6 2 Installation 10 7 Maintena...

Страница 3: ...If the battery is fully discharged it should be charged within 12 hours 6 Before maintenance batteries and equipment must be cut off firstly 7 Do not use cleaning solvents to clean batteries 8 Do not...

Страница 4: ...mpatible devices 1 2 4 When fire occurs only dry powder fire extinguishers can be used liquid fire extinguishers are prohibited 1 2 5 Do not disassemble batteries privately 2 Introduction This battery...

Страница 5: ...g core Expansion flexible configuration multiple battery modules can be parallel expansion capacity applicable to different standby time requirements Low power consumption the battery has the function...

Страница 6: ...4V Charging voltage 56 8 58 4V Charging current limiting 10A The default charging current is greater than 55A and the current limiting is on Standard charging current current 20A 0 2C Maximum continu...

Страница 7: ...t power lamp When the BMS is activated press reset button for 6 seconds and release the protection board is reset and the LED lights are lit for 1 5 seconds at the same time after the BMS is reset the...

Страница 8: ...default baud rate is bps 9600 can be expanded in parallel battery pack communication interconnection 4 3 3 RS232 Default baud rate bps 9600 Shenzhen TAICO Technology Co Ltd Building 12 Feicui Street X...

Страница 9: ...OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON 10 OFF ON OFF ON 11 ON ON OFF ON 12 OFF OFF ON ON 13 ON OFF O...

Страница 10: ...n Elimina tion Elimin ation Elimi natio n Stop discharge Temperature overcurrent short circuit reverse connection failure protection Elimin ation Alway s bright Elimina tion Elimina tion Elimin ation...

Страница 11: ...wing tools are needed to install batteries Use insulated tools to prevent accidental electric shock or short circuit If there is no insulation tool use insulation tape to cover all exposed metal surfa...

Страница 12: ...n constant 6 1 5 This area has little dust and dirt Attention If the ambient temperature is out of working range the battery pack will stops to work The optimal operating temperature of the battery ra...

Страница 13: ...of the rack beware of the battery slipping out Note when connecting the equipment the battery output positive and negative electrodes should be taken from the first group and the last group of batter...

Страница 14: ...he RST reset key to see if the failure is eliminated after the battery restarts If it can not be eliminated please contact the manufacturer to handle do not open the battery case For a multi battery p...

Страница 15: ...Protection ALM alarm indicator lights flicker RUN operation indicator lights out Cause analysis Ambient temperature may be too high or too low Solution when the temperature at the NTC end returns to...

Отзывы: