         TC-U9AF-MC/Z is a mini wireless magnetic contact with 

    

elegant design. Its ability of transmitting signal is strong, 

    

which can keep high sensitivity within 150m. Before installation, 

    

we need to learn its unique address code into the gateway.

       When install, please pay much attention to the mark on transmitter 
       and contact, keep them on same level as shown in the picture.

 

if someone 

       tries to open the door, once the transmitter and contact separate about 
       2.5cm,it will send alarm signal to alarm host, the user will get the alert.

2.Perimeters

Alarm output: alarm report,

recovery report,

tamper report,

low battery report, status report

Status report: after power on, or transmitter come to work, 
                        it will send status reports to gateway every 40min

Working environment: -10

50

14

-122

)

Dimension

:

T

ransmitter 69.5(L

)

*21.2

(

W

)

*

19.5

(

H

)

mm

             

 Contact 34.5

(

L

)

*

10

(

W

)

*

13.2

(

H

)

mm

Color: white

Network protocol: Zigbee IEEE802.15.4
Communication protocol: Zigbee HA protocol
Max transmitting frequency: 4dbm
Working frequency:2.4Ghz
Power supply: 3V(CR123A)

Working current: static

15uA

alarm

10mA

(when within Zigbee network,

27mA,in other case,

10mA)

 When alarm, the current increase instantly. After alarm, it 

    will enter into sleep mode.

 when the voltage gets down to 2.3V, the network gateway 

    will show it low battery. The living-checking time between 
    them is 40min. 

3.1 main functions

A.Open/Close door
    On phone app, it displays open/close door dialog box.
     1.when contact is close to the transmitter, the door is closed.
     2.when contact is getting away from the transmitter, the door is opened.
B. Tamper function
     There are two buttons on the PCB as shown in the picture, Key1 is for tamper.
     Key2 is used to work with gateway.

3.2 Learn into Gateway

    Open the plastic cover, power on the transmitter, press Key2, the red led will last flash every 1s. 
    If done, the led wont flash.

3.3 Delete from Gateway

    Open the plastic cover, power on the transmitter, keep pressing the small button for more than 6s.At first, red led continue to light, 
    once the red Led begins to flash, it is deleted from the gateway successfully and reset automatically.

3.Function and Installation 

Key1

Key2

    Please pay much attention to the following points in case of failure to use after installation.

A.Do not mount on the place possibly 
    to be destroyed outdoor.

B.Do not mount at the loose place

C.When use as wireless detector, do not 
    mount near strong magnetism item.

3.4 installation precautions

contact

tamper

TC-U9AF-MC/Z