2.
Reader Settings
Reader ID : (Default=0)
SmaFinger Reader ID for multi link application. (ID: 0~99).
Interface : (Default=Wiegand)
SmaFinger can be set as Wiegand , RS232 or ABA-TK2 output.
Read Mode: (Default=Card Data Only)
a.
Card Data Only: Read card sector data only; If any error (ex. mifare key error), reader will show "Card
Invalid" status.
b.
Card Data or CSN (Card Serial Number): Read card sector data, If any error (ex. mifare key error),
reader will send the CSN to host.
c.
CSN Only: CSN read only.
Output Mode: (Default=Once)
a.
Once: Send data (or CSN) to host once.
b.
Continue: Keeping sending data (or CSN) to host till card remove.