tagarno 690600 Скачать руководство пользователя страница 2

2

1. 

Read the manual before you use the product

2. 

Use the product only as specified, or the protection supplied by the product can 

 

be compromised

3. 

Do not position the equipment so that it is difficult to operate the disconnecting 

 

device (appliance inlet of external power supply, equipment input connector)                                                                           

4. 

If fluids are spilled on the product, turn the system off immediately by pulling the power 

 

supply out of the electrical outlet

5. 

In case of fire close to the microscope, please turn off and disconnect the system

6. 

Avoid subjecting the lens to sharp or hard objects

7. 

Please do not connect the microscope, if visible damages appear

8. 

Do not dismantle any parts of the microscope, except where noted in the manual

9. 

Never disassemble or clean internal optical surfaces

10.  Use only the power supply provided from TAGARNO
11. 

Always turn off the system before unplugging, when possible

WARNINGS 

The product is a digital magnifying system consisting of a camera unit, PCBs, mechanical 
parts and a power supply. The product is intended for marketing worldwide and is designed for 

manual visual inspection.

INTENDED USE

Read all safety information before you use the product.

Please pay attention when you see a warning label on the product.

This product is for indoor use only.

You must not discard this electrical/electronic product in domestic household waste. 

Please dispose at your local recycling centre.

3.  TIPS

1.  INTENDED USE

2.  WARNINGS

1.      When applicable, use both hands to move the XY Table
2.      When applicable, use both hands to adjust the height of the product
3.      Avoid touching the lens 

4.  LASER POINTER WARNING

This product is equipped with a red laser pointer to enable easy alignment of the camera and areas of interest during the inspection process.
This product is a Class 2 laser product that complies with IEC60825-1 international standard for lasers.

These labels appear visible on the product:

CAUTION

Follow these safety instructions when using the product.

• 

Never look directly into the laser aperture

• 

Do not point towards anyone deliberately

• 

Leave the laser on only when necessary

• 

Always turn off power during service and maintenance

• 

Service may only be performed by trained personnel 
appointed by TAGARNO

This label is placed near the laser aperture
The label below is placed on the camera head

Содержание 690600

Страница 1: ...4 7 ASSEMBLING OTHER MOUNTING OPTIONS 6 8 ASSEMBLING LASER BEAM US ONLY 7 MANUAL TAGARNO FHD ZAP 9 OPERATION 10 10 TECHNICAL SPECIFICATIONS 12 11 PC REQUIREMENTS 14 12 MAINTENANCE 15 13 WARRANTY 15 14 ERGONOMICAL RECOMMENDATIONS 15 13 DECLARATION OF CONFORMITY 16 14 COMPLIANCE STATEMENTS 17 Go to tagarno com productmanuals to find manuals and tutorial videos ...

Страница 2: ...dwide and is designed for manual visual inspection INTENDED USE Read all safety information before you use the product Please pay attention when you see a warning label on the product This product is for indoor use only You must not discard this electrical electronic product in domestic household waste Please dispose at your local recycling centre 3 TIPS 1 INTENDED USE 2 WARNINGS 1 When applicable...

Страница 3: ...3 SMART GUIDE Smart guide Camera head with lens XKEY Control box Handles 5 YOU HAVE RECEIVED Flex arm advanced OPTIONS Flex arm inline Power supply ...

Страница 4: ...the table clam Assemble the bottom of the flex arm and the table mount NB For maximum stability at all magnfication levels make sure to mount the microscope on a sturdy table Assemble the flex arm by slotting the two arms together Mount the microscope to the top of the flex arm using the vesa bracket screws and handles TIP Find the How to Install tutorial video here www tagarno com installzap ...

Страница 5: ...se to decrease stability or counter clockwise to increase stability For extra stability in locked positions remove the rubber covering on the side of the flex arm ASSEMBLING FLEX ARM 2 2 For further stability tighten screws in numbered areas Then use the included finger screw to lock vertical movement ...

Страница 6: ...similar solution suitable for your process environment These mounting options are not included with your delivery To use angle bracket detach Vesa mount and mount the angle bracket to the microscope For safe operation mount only the microscope on support equipment capable of bearing a load of at least 6kg 3 times the weight of the microscope ...

Страница 7: ...7 8 ASSEMBLING LASER BEAM US ONLY IMPORTANT Laser beam attenuator Unmount lens protection cap when using this microscope ...

Страница 8: ...AGARNO 4 Power supply DC DC Jack Power socket 3000mm Input 12V 0 5A Use only the power supply provided by TAGARNO Brand Model Mean Well GEM18I12 Protection class II Input 100 240V 0 45 0 2A 50 60Hz Overvoltage category ll Output 12V 1 5A Max 5 ESD Ring Terminal Connector ESD Grounding point 3000mm ESD Grounding point Connect HDMI cable 1 USB 3 0 cable 2 control box 3 power supply 4 and ESD Electro...

Страница 9: ... box ASSEMBLING CONNECTING 3 3 Connect the power supply cable to the power supply battery and then to a electrical outlet Connect grounding cable to grounding point to ensure ESD of the microscope Connect USB 3 0 cable from the microscope to a PC ...

Страница 10: ...ter button down for 25 seconds 4 Release the center button and turn the power off 5 Turn the power back on and the microscope is set to factory setting 1080P60 Turn off on Laser on off WARNING Laser radiation when turned on Zoom in Zoom out Push both plus and minus to change from auto focus to manual focus You can now adjust the focus manually by using the plus minus buttons If you wish to focus o...

Страница 11: ... the required format by pressing the center button and use arrow keys left right to select between 6 different formats 6 Select OSD presets You need to choose between respectively ALWAYS ON OFF or TIMEOUT using the left right arrows in order to have the OSD Menu displayed continuously never or for 3 seconds at the time Continue by pressing the down arrow 7 Color boost The OSD menu gives you the po...

Страница 12: ...ds on flexarm Work depth Adjustable depends on flexarm and mounting Auto Monitor Detect No Power requirements Line voltage 100 240V 10 Line frequency 50 60Hz AC current consumption typ 70mA 100V 30mA 240V DC current consumption typ 0 5A 12V Environmental conditions Temperature Storage 5 to 60o C 23 to 140o F Operation 5 to 40o C 41 to 104o F Humidity range Storage 20 to 90 RH non condensing Operat...

Страница 13: ... Lens 2 3 4 5 and 10 Plan 1x TAGARNO Ring light White Height Adjustment Table Magnetic lens ring TAGARNO Ring light IR XY table XKEY Control Box TAGARNO Ring light UV Glass table Foot switch Backlight kit Cleaning kit FHD monitors per request Coaxial light Angle brackets Flex arms Circular tilting table FIELD OF VIEW MAXIMUM MINIMUM Lens X Direction Y Direction X Direction Y Direction 2 600 mm 23 ...

Страница 14: ...M with 2GB RAM Monitor resolution 1920x1080 recommended FULL HD 1080P 29 97 25HZ AND HD 720P 59 94 50 30 25HZ OS Desktop Laptop Windows 7 8 or 10 with DirectX 11 Memory 4GB CPU Intel Core Dual 3 0GHz or i3 2 4GHz 4th generation named 4xxx or newer Intel Core i3 3 2GHz 4th generation named 4xxx or newer Hard Disc Space 1GB required SSD type recommended Connections USB 3 0 xHCI host controller Intel...

Страница 15: ...be as follows TAGARNO warrants that the product will correspond with the specification at the time of delivery and will be free from defects in material and workmanship for a period of 24 months 2 years from date of invoice from Supplier This warranty covers a The replacement of defective parts b All labour costs to exchange defective parts in product c Complete functions test of product before re...

Страница 16: ...the product listed above consisting of a camera unit and a 12V power supply is in compliance with the following European directives 2006 25 EU 2014 30 EU 2014 35 EU By conforming to the following harmonized standards IEC 60825 1 2014 EN 61326 1 2013 IEC 61010 1 2010 THE DECLARATION IS ISSUED BY MANUFACTURER TAGARNO A S Class 2 Class B Basic Electromagnetic Environment IECEE CB Scheme Ref Certif No...

Страница 17: ...articular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an out...

Отзывы: