PRO CAN PUMP DUAL (PRO-CPD20)
Rev 1.6
2023/07/31
51/95
Copyright
©
2023 by TAEHA CORP. All Rights Reserved
7.4.3
When using the reference sensor P1+P2
➔
When P1 + P2 is set, the mode setting screen and supply pressure setting window are changed as
shown below.
This is a control method that consists of reference 1 and 2 sensors at the same time to prevent an
excessive pressure rise in the dispensing unit and supply unit.
➔
The reference 1 sensor is given the maximum pressure / bottom limit of pressure as shown
below.
➔
The reference 2 sensor is given the supply pressure / top limit of pressure as shown below.
List
Description
Set the pressure value of P2 dispensing unit.
If the pressure value in the P2 dispensing unit exceeds the top
pressure limit, the liquid transfer stops and an alarm is
triggered.
If the pressure value in the P1 supply unit drops below the
bottom pressure limit, the liquid transfer stops and an alarm is
triggered.
Set the pressure value of the P1 supply unit.