![tae TA Series Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/tae/ta-series/ta-series_instructions-and-operating-manual_813395064.webp)
Appendix 1 list of Parameters
State 16.11.15
Misprints and technical changes reserved
Page 14
10: PLC I/O
ID
Name
Value-Range
Default-Value
Unit
Access
403 OUT Polarity
00000000h ... FFFFFFFFh
FFFFFFFFh
RW
410 IO N_Inputs
0 ... 32
---
R
411 IO N_Outputs
0 ... 32
---
R
412 Valid Input
00000000h ... FFFFFFFFh
---
R
413 Valid Output
00000000h ... FFFFFFFFh
---
R
414 IO_ActIN
00000000h ... FFFFFFFFh
---
R
415 IO_ActOUT
00000000h ... FFFFFFFFh
---
R
11: Monitoring-Limits
ID
Name
Value-Range
Default-Value
Unit
Access
500 Drive Over-Temp Limit
0,0 ... 85,0
80,0
°Cel
RW
501 Drive Over-Voltage Limit
0 ... 800
780/390
V
R
502 Drive Under-Voltage Limit
0 ... 800
360/205
V
R
503 Drive Over-Current Limit
0,000 ... Par.74
---
A
R
504 Drive Brake-Chopper Off Voltage
1 ... 800
740/365
V
R
505 Drive Brake-Chopper On Voltage
1 ... 800
750/375
V
R
506 Motor Max Speed electr.
0,0 ... Par.75
---
rpm
R
507 Motor Max Speed mech.
0,0 ... Par.75
---
rpm
R
508 Motor Over-Temp Limit
0,0 ... 250,0
---
°Cel
RW
509 Motor Warn Temp Limit
0,0 ... 250,0
---
°Cel
RW
510 Speed detect Limit
0,0 ... Par.75
300,0
rpm
RW
511 Current detect Limit
0,00 ... Par.104
Par.28
A
RW
512 Delayed Message Current limit reached
0,0 ... 1000,0
5,0
s
RW
513 Drive Warn Temp Limit
0,0 ... 80,0
75,0
°Cel
RW
514 Under-Voltage delay time
0 ... 60000
---
ms
RW
12: Actual Values
ID
Name
Value-Range
Default-Value
Unit
Access
520 Act Speed
-1000,0 ... 1000,0
---
rpm
R
521 Ref Speed
-1000,0 ... 1000,0
---
rpm
R
522 Actual Current
0,00 ... 0,00
---
A
R
523 Motor Torque
0,00 ... 2147483647,00
---
Nm
R
524 Buss Voltage
0 ... 800
---
V
R
525 Motor Temp. Terminal 22
-320,0 ... 320,0
---
°Cel
R
526 Motor Pre.-Temp. Terminal 21
-320,0 ... 320,0
---
°Cel
R
527 Drive Temp.
-267,0 ... 267,0
---
°Cel
R
528 Actual Lead Speed
-1000,0 ... 1000,0
---
rpm
R
529 Machine Speed
0,000 ... 2147483647,000
---
--
R
530 Act Pulse Frequency
1,00 ... 20,00
---
kHz
R
531 Motor Current U
-100,00 ... 100,00
---
A
R
532 Motor Current V
-100,00 ... 100,00
---
A
R
533 Motor Current W
-100,00 ... 100,00
---
A
R
534 Brake Chopper Volt
0,0 ... 800,0
---
V
R
535 n-Controller Ref Speed
-1000,0 ... 1000,0
---
rpm
R
536 n-Controller Act Speed
-1000,0 ... 1000,0
---
rpm
R
537 n-Controller Deviation
-1000,0 ... 1000,0
---
rpm
R
538 n-Controller Output
-100,00 ... 100,00
---
A
R
539 Actual Current unfiltered
0,00 ... 0,00
---
A
R
540 ASM minimum flux
-32767 ... 32767
---
R
541 ASM rated flux
-32767 ... 32767
---
R
542 Flux Weakening
0,00 ... 0,00
---
A
R
546 Drive Working minutes
0 ... 59
---
min
R
547 Drive Working hours
0 ... 2147483647
---
h
R
548 Drive Operating minutes
0 ... 59
---
min
R
549 Drive Operating hours
0 ... 2147483647
---
h
R