background image

tado°  – Manual & Technical Documentation V1.1

2

Compatibility

tado° is compatible with almost all central heating systems, including:

•  combi, system and heat-only boilers
•  conventional and condensing boilers
•  common Y-, S- and W-plan setups
• 

hydronic underfloor systems

• 

electric underfloor systems with a maximum switching current of 6 A

•  air source and ground source heat pumps (heating only)
•  zoned systems (one Smart Thermostat per zone)
•  switched live systems
•  potential free (dry contact) systems
•  low voltage systems with analog interfaces
•  low voltage systems with digital bus interfaces

tado°‘s compatibility with specific heating systems can be checked at

www.tado.com

Compatibility

Model Predictive Control

tado° does not require presence or absence time programming. Patents have been 

filed for the algorithms which automatically adjust the heating output to the user‘s 

needs. A building model is automatically created for each household which allows 
tado°‘s proprietary model of predictive control to include weather forecasts in the  
control strategy and therefore optimize energy usage and comfort at home.

Location Based Heating

The tado° Smart Thermostat controls the temperature automatically depending on the 
residents location and distance from home and will only heat when it is really needed.

Encryption of Communication

Any communication between web browsers or smartphones and the tado° application 
servers is encrypted with TLS 1.2 (SSL) Encryption with a 2048-bit Extended Validation 

Certificate.

The communication between the tado° Bridge and the tado° Application Servers is 

encrypted with TLS 1.2 (SSL) using 256-bit elliptical curve encryption.

The radio communication between the tado° devices uses AES-CCM encryption. The 
key is exchanged by pairing the devices as part of the initial installation procedure.

Intelligence & Security

COMPATIBILITY CHECK

If tado° is bought online the compatibility is  
checked during the installation process.

In cases where tado° is bought from an 
installer, they will check the compatibility.

Содержание RU01

Страница 1: ...Manual Technical Documentation V1 1 tado Smart Thermostat tado Extension Kit ENGLISH...

Страница 2: ...mostat Usage Menu Structure Special States Pairing Reset Interfaces Correct placement of the Smart Thermostat as a Sensor Extension Box Usage Pairing Reset Mechanical Design Interfaces Bridge Installa...

Страница 3: ...rols heating based on sensor data from the tado Smart Thermostat Typically installed next to the boiler or replacing an existing external controller Compatible with the UK standard backplate 1 2 tado...

Страница 4: ...r each household which allows tado s proprietary model of predictive control to include weather forecasts in the control strategy and therefore optimize energy usage and comfort at home Location Based...

Страница 5: ...Schedule tado prepares hot water according to the settings in the dedicated hot water schedule It can be set in the web application Manual When set to Manual tado prepares hot water constantly Meanin...

Страница 6: ...mmediately after pressing the mechanical push button for activating the UI Please read the chapter Installation before installing CONTROL ELEMENTS The mechanical push button activates and moves throug...

Страница 7: ...Off Hot Water Auto Operation HEATING HOT WATER not supported by all heating systems 2 Operation Mode 2x button push 3 Change Settings 3x button push 1 State 1x button push 4 State 4x button push 5 Ho...

Страница 8: ...ion required by a press of the button Flash once in sequence before the possible error states loop starts Open window Legionnaires protection Update Empty battery Extension Kit has no radio link to Br...

Страница 9: ...and turned off Releasing the button Waiting until successfully paired Releasing the button Pairing for 1 minute Successfully paired Screen turns off Pairing Symbol Screen turns off Reboot screen appe...

Страница 10: ...ed against polarity reversal thus the order of connection does not matter When replacing wireless thermostats the additional purchase of the tado Extension Kit is recommended The tado Extension Box re...

Страница 11: ...maybe required which is provided by tado upon request Extension Box Please read the chapter Installation before installing Extension Box Usage LED Display LED ACTION MEANING Off No Power Blinking Conn...

Страница 12: ...t pins Jumper Serial number authentication code Backplate wiring diagrams Screws to fasten housing Holes for wall mounting Terminal blocks Wall Mounted Backplate 2 Tighten the screws at the bottom to...

Страница 13: ...Jumper Position 2 Switched Live This wiring option corresponds to a 230V dual relay programmer In case a UK stan dard backplate is present and wired as a 230V dual relay central heating and hot water...

Страница 14: ...router and the USB port to power via the power adapter Connect the ethernet port to the router and the USB port to power via the router USB POWER ADAPTER USB JACK ON ROUTER link router internet link...

Страница 15: ...89 416156640 INSTALLATION PROCESS Have the tado products at hand Create an account Select the heating system Register devices Professional installer booking Self installation with tado installation i...

Страница 16: ...ABS Colour white matte tado Bridge Model GW02 Dimensions circa 89 x 52 5 x 25 5 mm L x W x H circa 61 g Operating voltage 5 V Radio 868 MHz Mesh 6LoWPAN Material PC ABS Colour white matte Regulatory C...

Отзывы: