Automatic
T
setting-
T
room
0ºC
F
an speed
Mute
T
setting-
T
room
0ºC
F
an speed
Mute
1ºC
2ºC
Low
Low
1ºC
2ºC
Low
Low
3ºC
4ºC
Low
Low
3ºC
4ºC
Low
Low
≥
5ºC High
≥
5ºC High
Outdoor fan speed
Single speed motor starts or stop as soon as the compressor starts or stops.
4.4 The 4 way valve is interrupted.
4.5 Anti freeze routine : When the indoor coil temperature
≤
-1ºC and maintaining
for 5 minutes , both the compressor and outdoor fan are interrupted.The
resumption condition is that the indoor coil temperature
≥
7ºC.
5.
Dehumidification (Dry) mode
5.1 In the dry mode , the temperature setting is sellected by using the remote
controller . The temperature control ranges from 16 - 30ºC.The control unit
selects a run mode according to the temperature difference between the
room tempeature and temperature setting.
5.2 When the room temperature is above 2ºC higher than the temperature
setting , the system runs in the cooling mode.
5.3 When the difference between the room temperature and temperature setting
is equel to or lower than 2ºC , the system starts in Dry mode . In the Dry
mode , both the compressor and outdoor fan operate in the cycle of 10 min’
run and 6 min’ stop.
5.4 When Dry mode is operated , the outdoor fan motor starts or stops as soon
as soon as the compressor starts or stops.
9. CONTROL MODE