Special Remarks

Heating (

) Operation

Heating performance

Defrosting

POWER lamp

Because this air conditioner heats a room by drawing on the heat of the outside air

(heat pump system), the heating efficiency will fall off when the outdoor temperature
is very low. If sufficient heat cannot be obtained with this air conditioner, use another
heating appliance in conjunction with it.

When the outdoor temperature is low , frost or ice may from in the heat exchanger

coil, reducing heating performance. When this happens, a microcomputer defrosting
system will operate. At the same time the fan on the indoor unit stops ( or runs at
very low speed in some cases). Heating operation restarts after several minutes.
(This interval will vary slightly depending upon the outdoor temperature and the way
in which frost forms).

For several minutes after the start of heating operation, the indoor fan will not start

running until the indoor heat exchanger coil has warmed up sufficiently. This is
because the COLD DRAFT PREVENTION SYSTEM is operating.

The POWER lamp also remains lit during defrosting or when the compressor has

been turned off by the thermostat when the system is in the heating mode.

In the event of power failure, the unit will stop. When the power is resumed,

the unit will restart automatically after three minutes.

In heating or cooling operation. Some plastic parts may expand of shrink due to a

sudden temperature change. In this event, a clicking sound may occur. This is normal,
and the sound will soon disappear.

The remote control unit sends the temperature signal to the air conditioner regularly

at three-minute intervals. If the signal from the remote control unit stops for more
than ten minutes due to the loss of the remote control unit or other trouble, the air
conditioner will switch to the temperature sensor which is built into the indoor unit
and control the room temperature. In these cases, the temperature around the
remote control unit may differ from the temperature detected at the air conditioner s
position.

Power failure

during operation

Clicking Sound

Clicking sound is

heard from the air

conditioner

Содержание TGI-07H

Страница 1: ...TGI 12H INSTRUCTION MANUAL TGI 09H SPLIT TYPE AIR CONDITIONER TGI 07H...

Страница 2: ...ontrol Automatic Switching between Cooling and Heating Hot start Heating System Automatic Restart Function for Power Failure Anti Mold Filter High Power Running This function moves a flap up and down...

Страница 3: ...hooting Schematic diagram Pardon not to inform you if the contents of the manual changes 1 2 3 8 16 18 18 19 WARNING CAUTION Alert Symbols The symbol refers to a hazard or an unsafe practice which can...

Страница 4: ...this only for its intended purpose as described in this instruction manual 1 All wiring must conform to the local electrical codes 2 Each unit must be properly grounded 3 Wiring must be done by a qual...

Страница 5: ...nsing Unit Drain Hose Air from the room is drawn into this section and passes through air filters which remove dust Conditioned air is blown out of the air conditioner through the air outlet The wirel...

Страница 6: ...p HIPOWER lamp This section picks up infrared signals from the remote control unit transmitter This lamp lights when the air conditioner is in the operation mode But the compressor may not run at this...

Страница 7: ...1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Flap angle indication 8 Sweep indication 9 Indoor unit sensor ON OFF A A 3 Set temperature 16 30 When set to 28 Current temperature in...

Страница 8: ...s switched on If the unit is turned off only the mode that was set previously is still displayed For details see Night Setback Mode When you press this button in the HEAT DRY or COOL mode the mark app...

Страница 9: ...the display And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly set thermostat and the room temperature and automat...

Страница 10: ...s when the remote control unit s display fails to light e NOTE When using the remote control unit always point the unit s transmitter head directly at the air conditioner s receiver To ensure that the...

Страница 11: ...rt the air conditioner press the ON OFF operation button Press the TEMP setting button to change the temperature setting to the desired temperature Adjustable temperature range 30 max 16 min NOTE Set...

Страница 12: ...om temperatureand set temperature is FAN SPEED High Medium Low RT T 5 T 5 RT T 3 Rt T 3 Mild drying mode When difference between room temperature and set temperature is FAN SPEED High Medium Low RT T...

Страница 13: ...on settings 1 2 3 4 5 6 SWEEP COOL and DRY HEAT A Sweep function The flap starts moving up and down to deliver air over the sweep range B Automatic Function The flap moves up and down automatically fr...

Страница 14: ...ure when night setback was selected This Enables you to save energy without sacrificing comfort This Function is convenient when gentle cooling is needed 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Setting temper...

Страница 15: ...fter the length of time set for TIMER OFF elapses the unit stops operating Setting Procedure The display depicted at left indicates that the air conditioner will stop operating in five hours STEP 1 Pr...

Страница 16: ...stop operating and then press the ON OFFoperation button again The 1 Hour Timer function is now cancelled and the unit operates normally This operation makes higher or lower temperature airflow than u...

Страница 17: ...ently This is because the COLD DRAFT PREVENTION SYSTEM is operating The POWER lamp also remains lit during defrosting or when the compressor has been turned off by the thermostat when the system is in...

Страница 18: ...unit to clean it This will damage the internal components and cause an electric shock hazard Clean the casing and grille of the indoor unit with a vacuum cleaner brush or wipe them with a clean soft...

Страница 19: ...filter up into the unit and then lower the handle into the groove on the unit 2 After installing the anit mold filter press the locations marked by the arrows and close the air intake grille Air Clean...

Страница 20: ...igh for cooling or too low for heating 6 Outdoor temperature is too low 7 Defrosting system does not work In heating or cooling operation some plastic parts may expand or shrink due to a sudden temper...

Страница 21: ...ol range angle range Maximum length of the connect tube 19 TGI 09H AC 230V 50Hz 950W 950W 2500W 3000W 8m 80 15m 450m h R22 0 84kg 3 TGI 07H AC 230V 50Hz 750W 710W 2100W 2300W 8m 80 15m 340m h R22 0 70...

Страница 22: ...1 2 3 4 5 1 2 3 4 5 1 2 3 1 2 1 2 1 2 1 2 1 8 1 8 1 3 5 1 3 5 1 2 3 1 2 1 2 1 2 1 2 ROOM COIL SU COM CM FM VA FLAP FM PULSE IN SW PRY SEC 0 1 2 3 4 5 TRANSFORMER SENSOR SENSOR PLUG EVAPORATOR TERMINA...

Страница 23: ...OW AIR FRESH FILTER INDOOR UNIT INSTRUCTION MANUAL INSTALLATION MANUAL REMOTE CONTROL UNIT BATTERY NAIL SPECIAL BOLT SPECIAL COVER 1 1 1 1 1 1 1 2 6 6 1 OUTDOOR OUTDOOR OUTDOOR INDOOR INDOOR INDOOR IN...

Отзывы: