Coral IPx Office Installation Manual
Hardware Installation Procedure
2-45
Eq
uipment Insta
llation
2
0
The Coral IPx Office can operate as an AC powered system or as a DC powered
system. For DC powered systems, skip to
AC Powered Systems
This section describes how to connect the power wires to the IPx Office unit for AC
systems (when the PS Office AC power supply card is installed). See
.
1.
Route the AC power cord from the AC power receptacle to the AC connection
of the PS Office AC unit.
For 115 volt operation, when the power supply cord is not factory-supplied
the cord should be selected as follows:
Use a UL Listed/CSA Labeled Cord Set consisting of a minimum 18 AWG,
Type SVT or SJT three-conductor cord, terminating in a molded connector
body. The cord should have an IEC CEE-22 female configuration on one
end, and a molded-on parallel blade grounding type attachment plug rated
15A, 125V configuration (5-15P), at the other end.
2.
Do
not
insert the power cord into the AC receptacle at this time.
Figure 2-26 AC Power
Connection for One IPx
Office Unit
...................................................................................................
13 Connecting the Power Wires
Electrical Hazard. Verify that the AC power strip or outlet supplying the unit is easily
accessible and can be easily disconnected in the event of emergency. Verify that the
power strip or outlet is no higher than 64" (162.5 cm) from the floor.
slots 2 - 3
slots 4 - 5
slots 6 - 7
slots 8 - 9
slots 10 - 11
PS Office AC
Cat. No. 77440950200
OUTPUT:
+5V 6A
+3.3V 6A
DC
DC
DC
-48V 1A
INPUT:
100-240V 2.2A 50/60Hz
AC
ON
OFF
To AC
power outlet
Содержание Coral IPx Office
Страница 2: ......
Страница 4: ......
Страница 25: ...xxi Figure 11 10 WiFi Antenna Removal 11 18...
Страница 26: ......
Страница 28: ......
Страница 36: ...1 8 Introduction Coral IPx Office Installation Manual About this Manual 1 NOTES...
Страница 44: ......
Страница 52: ...2 8 Hardware Installation Procedure Coral IPx Office Installation Manual Site Inspection 2 NOTES...
Страница 96: ......
Страница 106: ...3 10 Initial Power up Tests Coral IPx Office Installation Manual Common Control Test 3 NOTES...
Страница 120: ...3 24 Initial Power up Tests Coral IPx Office Installation Manual Completing the Installation 3 NOTES...
Страница 122: ......
Страница 128: ...4 6 Software Installation Procedure Coral IPx Office Installation Manual Generic Feature Software Upgrade 4 NOTES...
Страница 138: ......
Страница 144: ...5 6 External Connections Coral IPx Office Installation Manual Main Distribution Frame MDF 5 NOTES...
Страница 182: ......
Страница 232: ...6 50 System Description Coral IPx Office Installation Manual System Configuration Options IPx Office 6 NOTES...
Страница 234: ......
Страница 258: ...7 24 Power Supply Coral IPx Office Installation Manual PS Office DC Power Supply Unit 7 NOTES...
Страница 260: ......
Страница 286: ...8 26 Common Control Cards Coral IPx Office Installation Manual MCB Office Card Main Control Board 8 NOTES...
Страница 302: ...8 42 Common Control Cards Coral IPx Office Installation Manual Compact Flash Disk 8 NOTES...
Страница 310: ...8 50 Common Control Cards Coral IPx Office Installation Manual DBM Card 8 NOTES...
Страница 312: ......
Страница 372: ...9 60 Shared Service Cards Coral IPx Office Installation Manual VoIP Media Gateway MG 9 NOTES...
Страница 382: ...9 70 Shared Service Cards Coral IPx Office Installation Manual Data Serial Ports RS 232E KB0 KB1 KB2 KB3 9 NOTES...
Страница 414: ...9 102 Shared Service Cards Coral IPx Office Installation Manual Accessory or Alarm Relay 3 Major Minor Alarm 9 NOTES...
Страница 420: ......
Страница 488: ......
Страница 494: ...11 8 System Networking Coral IPx Office Installation Manual NTU Office Card Description 11 NOTES...
Страница 509: ......