background image

6

7

FASTENING TOOLS

 FOR THE PROFESSIONAL

•  

Never point any power tool at yourself or at any other 

person.

 While working, hold the tool in such a way that no 

injuries can be caused to the head or to the body in the event of 
possible recoil.

• 

Do not drive fasteners on top of other fasteners.

•  

Do not use this tool to fasten electric cables.

 This tool is not 

designed for the installation of electric cabling and may damage 
electric cables which could lead to injury by electric shock or  
fire hazards.

Features

 (Fig. A) 

1. Trigger 
2.  Firing Mode Selector 
3.  Quick Release Plug (Euro Fitting) 
4. Feeder 
5.  Magazine 
6.  Non-Marking Nose 
7.  Depth Adjustment Wheel 
8.  Air Deflector

Set up 

Your air tool is fully assembled when you receive it. Before using it, 
attach the air line and desired air system accessories. See Fig. B for 
the recommended accessories and connection order. Be sure the 
air hose is de-pressurised when installing or removing adaptors to 
the air line.

Connecting The Tool to an Air Supply 

(Fig. B)

 

•   Determine if the tool needs oil and, if necessary, place two 

drops of oil in the air plug as shown in Fig. B. If you are using an 
automatic in-line oiler, check and add oil if necessary.

•   Turn the compressor on and set the regulator to the proper 

pressure for the size and type of fastener being used.

•   Connect the tool to the air supply.

Loading the Tool with Nails

 (Fig. C) 

•   Push the strip of fasteners into the back of the magazine with the 

nail head at the top of the slot (1).

•   Allow fasteners to slide to the front of the magazine.
•   Depress and hold the button on the magazine feeder (2). Pull 

feeder back towards the rear of the magazine.

•   Release the feeder button and allow the feeder to slide back and 

lock onto rear of fasteners (3).

Adjusting the Depth 

(Fig. D)

 

The driving depth of the fasteners can be set with the depth 
adjustment wheel (7).
•  

Fasteners are not driven in deep enough:

 To increase the 

driving depth, turn depth adjustment wheel to the left.

 or
•  

Fasteners are driven in too deeply:

 To reduce the driving 

depth, turn the depth adjustment wheel to the right.

•  

Test the new driving depth on a test workpiece. Repeat steps 
above as required.

Operating the Tool 

Test the driving depth in a sample piece of wood before using. See 
section ADJUSTING THE DEPTH.
•   Connect the tool to the air supply. Make sure the air pressure is 

in correct range denoted in section of TECHNICAL DATA.

•   Load fasteners as directed in the section called LOADING THE 

FASTENERS.

•   Hold the body and press the drive guide to work surface, be sure 

the tool is straight and then gently depress the trigger to drive  
the fastener.

•  Lift the tool off the work surface.

Firing Modes 

(Fig. E)

 

The tool has two driving modes:

Sequential fire:

•   Choose the correct mode before firing by rotating the FIRING 

MODE SELECTOR SWITCH (Fig. E).

•   Put the nose on the working surface, lightly push the tool 

toward the working surface until the SAFETY BRACKET is 
depressed, then, depress the trigger to drive the fasteners. Whilst 
maintaining contact with the working surface, the tool will drive a 
fastener each time the trigger is depressed.

Contact trip (Bump fire):

•   Choose the correct mode before firing by rotating the FIRING 

MODE SELECTOR SWITCH (Fig. E).

•   First, depress the TRIGGER, then, repeatedly impact the SAFETY 

BRACKET, the tool can repeatedly drive the fasteners.  
The tool will drive one fastener when the safety bracket is 
impacted once.

NOTE:

 The air deflector (Fig. F) is directional and can be rotated 

through 360°.

Regular Maintenance 

•   Frequent, but not excessive, lubrication is required for best 

performance. Oil added through the airline connection will lubricate 
internal parts. An automatic airline oiler is recommended but oil 
may be added manually before every operation or after about 
1 hour of continuous use. Only a few drops of oil at a time are 
necessary. Too much oil will collect inside the tool and be blown 
out during the exhaust cycle. ONLY USE PNEUMATIC TOOL OIL. Do 
not use detergent oil or additives, as these lubricants will cause 
accelerated wear to the seal in the tool.

•  Use a small amount of oil on all moving surface and pivots.
•   Dirt and water in the air supply are major causes of pneumatic 

tool wear. Use a filter/oiler for better performance and longer 
life. The filter must have adequate flow capacity for the specific 
application. Consult the manufacturer’s instructions for proper 
maintenance of your filter.

•   Keep tools clean for better and safer performance. Use  

non-flammable cleaning solutions (CAUTION: Such solutions may 
damage O-ring and other tool parts) only if necessary - DO NOT 
SOAK.

PROBLEM

CAUSE OF PROBLEM

SOLUTION

Air leaking at trigger area

1.  O-ring in trigger valve is damaged.
2.  Trigger valve head is damaged.
3.   Trigger valve stem, seal or O-ring  

is damaged.

1.  Check and replace O-ring.
2.  Check and replace trigger valve head.
3.   Check and replace trigger valve stem, 

seal or O-ring.

Air leaking between body and front plate

Damaged piston O-ring or bumper

Check and replace O-ring or bumper

Air leaking between body and cylinder cap

1.  Screw loose.
2.  Damaged seal.

1.  Tighten screws.
2.  Check and replace seal.

Blade driving fastener too deeply

1.  Worn bumper.
2.  Air pressure is too high.

1.  Replace bumper.
2.  Adjust the air pressure.

Runs slowly or has power loss

1.  Insufficient oil.
2.  Insufficient air supply.
3.  Broken spring in cylinder cap.
4.  Exhaust port in cylinder cap is blocked.

1.  Lubricate as instructed.
2.  Check air supply.
3.  Replace spring.
4.  Replace damaged internal parts.

Tool skips a fastener

1.  Worn bumper or damaged spring (53).
2.  Dirt in front plate.
3.  Inadequate airflow to tool.
4.  Worn or dry O-ring on piston.
5.  Damaged O-ring on trigger valve.
6.  Cylinder cap seal leaking.

1.  Replace bumper or pusher spring.
2.  Clean drive channel of front plate.
3.  Check hose and compressor fittings.
4.  Replace O-ring or lubricate.
5.  Replace O-ring.
6.  Replace seal.

Fasteners are jammed

1.  Joint guider is worn.
2.  Fasteners are wrong size or damaged.
3.  Magazine or front plate screws are loose.
4.  Blade in piston assembly is damaged.

1.  Replace joint guider.
2.   Use the recommended and undamaged 

fasteners.

3.  Tighten screws.
4.  Replace piston assembly.

Tool will not drive down tight

1.  Worn blade in piston assembly.
2.  Lack of power.
3.  Slow cycling and loss of power.

1.  Replace piston assembly.
2.  Adjust to adequate air pressure.
3.   Check cylinder cap spring for broken 

coils or reduced length. Check if exhaust 
port of cylinder cap is restricted.

Trouble Shooting 

Stop using the tool immediately if any of the following problems occur. Serious personal injury could occur. Any repairs or replacements must be 
completed by a qualified person or an authorised service centre only.

Отзывы: