Tactical TTC Скачать руководство пользователя страница 7

Tactical Controls Limited

Time and Temperature Controller

Instruction Manual

Technical specification

Sensor input

PRT100

Level detection

Volt-free input for level detection

Setpoint

0 to 99ºC; default to 50°C

Temperature Control

ON/OFF with 1ºC hysteresis

Temperature Output

Relay 10A max. (5A continuous) 240Vac

Timer Control

0 to 99 minutes; default to 10 minutes

Timer Output

Relay 10A max. (5A continuous) 240Vac

Display

Two 7-segment LED green for temperature
Two 7-segment LED green for timer
4 status indicating LED; 2 green and 2 amber

Keys

6 positive feedback tactile push buttons

Connection

6 way multi-pole connectors; 2 for mains supply, 2 for temperature
output, 2 for timer output
3 way plug-in connector for temperature sensor input
2 way plug-in connector for level detector input

Supply

240 Vrms +/-15% 50Hz 10VA maximum with all outputs OFF

Dimensions

250mm(L) x 80mm(W) x 50mm(H) max.

Mounting positions

Fixing centres 105mm x 70mm; 6 x M3 x 8.0 studs

Weight

500g max.

Temperature

0 to 50 ºC operating; -20 to 65 ºC storage

Warranty

12 months return to base

TTC\IM

Page 7

12 October 1999

Issue 0.1

Содержание TTC

Страница 1: ...s Limited This document contains proprietary information which is protected by copyright All rights reserved This document or parts thereof may not be reproduced in any form without written permission...

Страница 2: ...uid but most units require the application of additional heat for control at a given set temperature The cleaning process is set to run for a set time and then the unit is automatically switched off B...

Страница 3: ...s indicating LEDs control and setting push buttons and output circuitry for temperature and timer The operator panel is mounted on the fascia plate inside the cleaning unit using six nuts and washers...

Страница 4: ...includes time setting and setpoint temperature The amber LEDs are for the status of the heater and timer output The time and temperature are indicated and controlled separately on the panel To activa...

Страница 5: ...ted to a 2 way connector CONN2 on the PCB The 240Vac mains supply the heater output and the timer output are connected to a 6 way free plug Mains and output connector diagram MAINS NEUTRAL BLUE MAINS...

Страница 6: ...FIRST ISSUE ALL DIMENSIONS ARE IN MM GENERAL TOLERANCE X 0 5 X X 0 05 1 90 0 90 0 6 X 3 5 240 0 50 060 0 46 0MAX 6 X M3X20 6 X M3X8 R4 0 95 0 105 0 95 0 105 0 80 0 70 0 50 0 220 0 26 5 39 0 13 0 35 0...

Страница 7: ...temperature Two 7 segment LED green for timer 4 status indicating LED 2 green and 2 amber Keys 6 positive feedback tactile push buttons Connection 6 way multi pole connectors 2 for mains supply 2 for...

Страница 8: ...code TTC You are welcome to order the unit by code or description TTC Time and Temperature controller Supplier information Tactical Controls Limited Unit 1 Parkland Business Centre Chartwell Road Lanc...

Отзывы: