Tactical Controls Limited

72TS Train Number Box

Instruction Manual

Operation parameters

Parameters   in   the   ACC   are   accessed   by   pressing   the   scroll   button.   All   the   adjustable
parameters can be set within their limits using the UP and DOWN button.

The following is the list of parameters:

Symbol Description

Low Limit

High Limit

Default

Unit

t

Air temperature

0

99

°C

a

Alarm

1

31

S

Setpoint

16

35

22

°C

H

Heat Off/On

0=Off

1=On

1

F

Fan Off,low,med,high

0=Off

3=high

3

P

Proportional band

1

5

3

°C

o

Power output

0

99

%

h

Heatsink temperature

0

99

r

Zero reference

0

FF

Eng.unit

n

Span reference

0

FF

Eng.unit

1

Air alarm setting

50

90

60

°C

2

Heatsink alarm setting

50

90

65

°C

3

Minimum Power setting

0

99

0

%

The default display on the remote unit is the air sensor temperature [Air temperature - t]. This
will change to alarm display if there is active alarm.

In   user   mode   (default),   only   Measured   temperature,   Setpoint,   Heat   and   Fan   settings   are
accessible.

The   other   parameters   are   only   available   in   Engineering   mode.   This   mode   is   entered   by
pressing any one of the 3 push buttons on the remote unit when switching on the power to the
remote unit.

There are display only parameters such as Power output, Zero reference and Span reference
which for test and diagnostics only.

Configuration   parameters   such   as   Proband,   Air   alarm   setting,   Heatsink   alarm   setting   and
Minimum Power setting are also included.

72TSTNB Instruction Manual.doc

Page 12

2 March 2007

Issue 1.0

Содержание 72TS

Страница 1: ...f may not be reproduced in any form without written permission of the publishers The information in this document is subject to change without notice and should not be construed as a commitment by Tac...

Страница 2: ...4 Installation 5 Protection 5 Connection diagram 6 Connection terminals base unit 7 Connection terminals remote unit 8 Layout diagram base unit 9 Layout diagram remote unit 10 Dimensional drawing bas...

Страница 3: ...urtain ACC When the measured temperature is lower than the setpoint temperature the output will cycle between its minimum and maximum output settings All user adjustments are by means of front panel p...

Страница 4: ...s standard Control output Opto triac outputs are used for the control of heater output The rating is 3 phase 3 wire 415Vac 12KW max Relay outputs are used for the control of the fan speed high medium...

Страница 5: ...is connected to a 6 way connector marked N Lo Md Hi The sensor input air sensor is connected to a 2 way connector marked AIR on the base unit The sensor is not polarity sensitive The BMS control logic...

Страница 6: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Connection diagram 72TSTNB Instruction Manual doc Page 6 2 March 2007 Issue 1 0...

Страница 7: ...n medium speed Hi Fan high speed BMS BMS control logic normally closed volt free contact BMS BMS control logic normally closed volt free contact AIR Air sensor non polarised AIR Air sensor non polaris...

Страница 8: ...Box Instruction Manual Connection terminals remote unit Terminal Description 7V Supply from base unit 0V Supply from base unit B RS485 Comms to base unit A RS485 Comms to base unit 72TSTNB Instructio...

Страница 9: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Layout diagram base unit 72TSTNB Instruction Manual doc Page 9 2 March 2007 Issue 1 0...

Страница 10: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Layout diagram remote unit 72TSTNB Instruction Manual doc Page 10 2 March 2007 Issue 1 0...

Страница 11: ...Tactical Controls Limited 72TS Train Number Box Instruction Manual Dimensional drawing base unit 72TSTNB Instruction Manual doc Page 11 2 March 2007 Issue 1 0...

Страница 12: ...50 90 60 C 2 Heatsink alarm setting 50 90 65 C 3 Minimum Power setting 0 99 0 The default display on the remote unit is the air sensor temperature Air temperature t This will change to alarm display i...

Страница 13: ...lifted by several degrees depending on the Fan setting For example when the setpoint is 20 and the fan is set at high speed 3 the control setpoint will be 20 8 28 Internal setpoint lift due to air ch...

Страница 14: ...e heatsink sensor detects the temperature of the heatsink above 65 C Heatsink sensor failure Code 16 this is triggered when the heatsink sensor is open circuit typically when the heatsink sensor is br...

Страница 15: ...the heater switching devices Fan Output 3 off Relay for High Medium and Low Fan setting 3A max 240Vac Display Three 7 segment LED red for parameter display Push buttons 3 positive feedback tactile pus...

Страница 16: ...ith 415V supply and 12KW load maximum or ACC 6 00 is an Air Curtain controller with 240V supply and 6KW load maximum Ambirad Part numbers Remote Unit 900306 Base Unit 6KW to be confirmed Base Unit 9KW...

Отзывы: