![Tactic TTX402 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/tactic/ttx402/ttx402_instruction-manual_3175426014.webp)
14
●
Do not allow chemicals to come in contact with any parts of the radio system.
Substances such as glow fuel, gasoline, CA glue, etc. could permanently
damage plastic parts of the radio system.
●
If NiCd batteries were installed in the transmitter, remove the batteries before
placing the radio in long-term storage.
TROUBLESHOOTING
RANGE IS SHORT
Interference – check Rx antenna installation. Rx may need to be located to a
different position in the model for better reception. Low Tx or Rx battery – replace
the batteries or recharge if applicable. Crash damage – send the radio to Hobby
Services for repair.
RUN TIME IS SHORT
Low Tx or Rx batteries – replace or recharge the batteries. Obstructed servo
linkages causing excess battery drain – free the linkages / pushrods.
Tx POWER SWITCH ON BUT SERVOS DO NOT FUNCTION
Tx or Rx batteries are low – replace or recharge the batteries. Power is not
applied to the Rx – re-apply adequate power to the Rx. Rx is not binded to the
Tx properly – perform binding process again.
INTERFERENCE OR SERVOS GLITCHING
Out of range – operate the model more closely to the Tx. Outside radio interference
from pagers, strong industrial or other commercial transmitters in the area - check
your local R/C club regarding local operation.
CONTROL SURFACE MOVES IN THE WRONG DIRECTION
Reverse the direction of movement of the affected channel in the setup of the Tx.
INTERNAL CHARGER DOES NOT RECOGNIZE BATTERY
Make sure battery is connected properly. Check for faulty connection or wiring.
Replace battery.
CHARGE DOES NOT STOP AFTER 45 MINUTES
Internal problem might exist. Disconnect battery IMMEDIATELY and contact
Hobby Services.
BATTERY VOLTAGE LOW AFTER CHARGE IS COMPLETED
Battery might be defective and requires replacement. Backup safety timer might
have expired before full charge was reached – disconnect, then reconnect the
battery to complete the charge process.
EXTERNAL AILERON ACTUATOR SERVO DOES NOT FUNCTION
Connected to wrong input. See page 6 for proper connection. Incorrect servo plug
polarity.
TACJ2402 Mnl.indd 14
TACJ2402 Mnl.indd 14
4/20/2011 9:51:29 AM