4
04-19
RECOMMENDED SPARES & ACCESSORIES
FAULT DIAGNOSIS
The following simple checks may be performed by the operator. If the machine is still not working, please contact your local Service Agent:
Trouble
Reason
Remedy
Machine is not working
Lack of voltage/electrical supply
Check fuse *, power cord, plug and socket outlet
Loss of vacuum suction
Recovery tank incorrectly fitted
Refit the recovery tank
Recovery tank lid is incorrectly fitted
Refit the recovery tank lid
Recovery tank is full
Empty recovery tank
Vacuum hose is blocked
Check vacuum hose for blockages and signs of damage
Vacuum head blocked
Check vacuum head for blockages and signs of damage
Brush not rotating
Brush jammed with debris
Check brush for debris and signs of damage
Motor overload cut-out operated
Reset motor overload cut-out
Machine is not spraying solution
Can you hear the pump running?
If no, please contact your Service Agent.
If yes, see below.
Blocked jet
Check jet for blockages and signs of damage
Solution filter is blocked
Check solution filter for blockages and signs of damage
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.