background image

4

General instructions for PFX1080 series Extractors

Congratulations on your purchase of a Powr-Flite extractor. You are now equipped to handle any and all commercial carpet
cleaning jobs.

Shipping and Damage

This equipment is thoroughly inspected, tested, and packaged to provide equipment in good operating condition. It is beyond
our control after the equipment is turned over to a freight carrier. The freight carrier received and signed for the equipment in
good condition. Consequently, it is most important to protect your interest by carefully complying with the following instructions:

Please inspect your cartons for any damage (including concealed damage) that might have occurred during shipment. Any dam-
age is the responsibility of the freight carrier and should be reported to the freight carrier immediately. It is your responsibility to
issue a claim and to receive compensation from the freight carrier for any damage done in transit. Damage of this sort is not
warranted.

Follow these easy step-by-step instructions to ensure proper operating performance.

1.  Fill up the fresh water solution tank with tap water that is

120-135 degrees and approved carpet cleaning chemical,
if you are not pre-spraying your chemical on the carpet.

2.  Attach two 12 gauge extension cords (NOT INCLUDED)

(one cord for non-heated models) to each of the pigtail
cords located on the lower backside of the unit. The red
pigtail powers the heater while the black pigtail powers
the vacuum motors and pump.

3.  Plug each extension cord into a separate and grounded 20

amp wall socket circuits. When this is accomplished the
green indicator light will be lit (on heated models).

4.  Attach the hose system to the unit and to your carpet

wand.

5.  Turn on the heater and the pump to the "on" position,

(only pump on non-heated models). When the heater is on,
the orange indicator light on the switch panel will be lit.

6.  With the solution line attached to the wand and the achine,

prime the pump by squeezing the trigger on the wand
releasing the water (hold wand tip over solution tank to
put water back into solution tank). This will pump water
into the heater and get any air out of the solution line. Let
the heater heat up this will take 3 to 5 minutes. *Prime
pump on 400 p.s.i. models with prime hose (included).

7.  Turn vacuum switches to the "on" position one at at time

to begin cleaning.

8.  Anyone designated to operate this equipment must read

and thoroughly understand all instructions and precau-
tions prior to use.

9.  Never use equipment out of doors or in the rain.

10.  Never use flammable or explosive materials in or around

this equipment!

11.  When vacuum tank is full, empty by using dumping valve

on the front of the machine. If a pail is used to empty the
vacuum waste tank, do not use the same pail to fill the
solution tank as this can result in putting dirt and grit into
the solution line that can plug filters, orifices, and general-
ly degrade the solution line system (do not reuse solu-
tion).

12.  To empty solution tank, detach the wand from the end of

the vacuum hose and insert the vacuum hose into the
solution tank. Turn the vacuum switches to "on" position
and transfer solution to vacuum tank and dispose of as
outlined in #11. Clean vacuum stack filter at this time.

Содержание Powr-Flite PFX1080AW

Страница 1: ...WARNING OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT PFX1080 Man 7 2008 Midsize Extractor OPERATORS MANUAL AND PARTS LIST Model PFX1080 SERIES...

Страница 2: ...d cord or plug If unit is not working properly because it has been dropped dropped into water left outdoors or damaged in any way contact an authorized service center 5 DO NOT handle plug or appliance...

Страница 3: ...inserted into an appropriate 12 gauge 3 prong extension cord This unit is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug illustrated in Fig A This unit is for u...

Страница 4: ...to a separate and grounded 20 amp wall socket circuits When this is accomplished the green indicator light will be lit on heated models 4 Attach the hose system to the unit and to your carpet wand 5 T...

Страница 5: ...open 8 At the end of each day run the vacuum for 3 minutes with lid open and filter off Safety Precautions These precautions are designed with the safety of the operator the equipment and others in mi...

Страница 6: ...for steam type extraction equipment The use of any chemicals with abrasive additives voids the warranty 5 Do not use any replacement parts except those specified on the parts list Performance of the m...

Страница 7: ...E EXTRACTOR BASE X9441 22 SPACER CASTER 72783A 23 NUT 8 32 KEPS X8256 ref description order 24 NUT 10 32 KEPS 7BF008 25 NUT PUSH 1 2 7GL002 26 NUT KEP 10 24 ZINC 7BF003 27 PLASTIC VACUUM CHAMBER X9467...

Страница 8: ...BOW PC49 2 4 1 4 FLAT WASHER X8235 4 5 CLAMP DISCHARGE VALVE X9448 1 6 HINGE SOLUTION TANK LID X9450 1 7 LID SOLUTION TANK X9451 1 8 NUT 8 32 KEPS ZINC X8256 3 9 SCREW SHEET METAL 8X3 4 BLACK X9349 3...

Страница 9: ...2 3 OD X9461 1 12 GASKET DRAIN OUTER 1 8 ID 2 8 OD X9462 1 13 GASKET LID 8 ODX6 5 8 ID 1 8 THICK PX103G 1 14 GASKET SWITCH WIRES MID SIZE EXTRACTOR X9454 1 ref description order qty 15 HANDLE MID SIZ...

Страница 10: ...end screen by round squeezing slightly by hand until there is an obvious space between ball and inside of screen Foam dirty solution 1 Foam from carpet by 1 Use additional coming out of vacuum passing...

Страница 11: ......

Страница 12: ...other instructions for a period of 5 years from date of purchase on housings and frame 3 years on heater 1 year on pump vac motor and parts and workmanship In case you as our customer meet any trouble...

Отзывы: