Taco Zone Sentry Series Скачать руководство пользователя страница 3

WARNING: Wiring connec-
tions must be made in
accordance with all applic-
able electrical codes.

CAUTION: To prevent elec-
trical shock, disconnect
electric power to system at
main fuse or circuit breaker
box until installation is
complete. When a service
switch is installed, more
than one disconnect switch
may be required to deener-
gize this device for servic-
ing.

Zone Sentry Zone Valve Wiring Diagrams

LED

Motor

Circuit

End Switch

c

w/y

Simplified Internal

Schematic:

Thermostats

Transformer

To “T” Terminals
on Boiler Control
Transformer Relay

T

T

Up to 12 Valves per

40va Transformer

L1 (Hot)

L2

24 v

End Switch

Rh/Rc
w/y

Rh/Rc
w/y

Rh/Rc
w/y

w/y

c

End Switch

w/y

c

End Switch

w/y

c

L1 (Hot)

L2

Thermostat

To “T” Terminals

Motor

See Chart

See Chart

Red

Red

End Switch

Motor Wire Color

Honeywell = Yellow

Erie = Black

Sparco = Orange/Yellow

Honeywell, Erie and Sparco Wire Leads

Wiring a Taco Zone Sentry Zone Valve to Replace a
Honeywell, Erie or Sparco Valve:

Honeywell and Erie Terminal Block

L1 (Hot)

L2

Thermostat

To “T” Terminals

Motor

End Switch

TH

TR

TR

TH

ES

ES

L1 (Hot)

L2

Thermostat

To “T” Terminals on Boiler

Control Transformer Relay

Taco Zone Sentry Zone Valve

c

End Switch

w/y

Wiring a Taco Zone Sentry Zone Valve to Replace a
Flair or Taco 3-Wire Valve:

Taco Zone Sentry Zone Valve

Taco 570 Series

L1 (Hot)

L2

Thermostat

To “T” Terminals

Motor

End Switch

1

2

3

Flair

L1 (Hot)

L2

Thermostat

To “T” Terminals

Motor

End Switch

1

2

3

45

L1 (Hot)

L2

Thermostat

To “T” Terminals on Boiler

Control Transformer Relay

c

End Switch

w/y

Wiring a Taco Zone Sentry Zone Valve to Replace a
White Rodgers Valve:

L1 (Hot)

L2

To “T” Terminals on Boiler

Control Transformer Relay

Taco Zone Sentry Zone Valve

46

5

L1 (Hot)

L2

To “T” Terminals

Motor

End Switch

6

4

White-Rodgers (1311 or 1321)

4

56

Thermostat

5

2

3

1

Thermostat

c

End Switch

w/y

Typical Zone Sentry Zone Valve Wiring:

NOTE: Some power robbing thermostats require the use of a resistor (always use the resistor provided
by the thermostat manufacturer with the Zone Sentry). Consult the thermostat instructions for the
resistor installation.

Содержание Zone Sentry Series

Страница 1: ...e valve Cool valve quickly with a wet rag 4 Solder build up on the ball valve may prevent proper opening and closing of the valve Rotate the manual operation button several times to loosen any possible build up 5 Valve body can be submerged for leak testing before the operator is attached Operator Installation Wiring 1 Valve operator may be attached to the valve body in either direction see Figure...

Страница 2: ... as the thermo stat is calling the unit is powered 4 Once the thermostat is satisfied the green LED will turn OFF and the valve will rotate 90 into its nor mal position or non powered position For exam ple If the actuator is an NC normally closed ver sion the operator would open the valve when the thermostat calls Once the thermostat is satisfied the operator would then rotate the valve 90 to its ...

Страница 3: ...e or Sparco Valve Honeywell and Erie Terminal Block L1 Hot L2 Thermostat To T Terminals Motor End Switch TH TR TR TH ES ES L1 Hot L2 Thermostat To T Terminals on Boiler Control Transformer Relay Taco Zone Sentry Zone Valve c End Switch w y Wiring a Taco Zone Sentry Zone Valve to Replace a Flair or Taco 3 Wire Valve Taco Zone Sentry Zone Valve Taco 570 Series L1 Hot L2 Thermostat To T Terminals Mot...

Страница 4: ...amination and repair Any Taco product or part not installed or operat ed in conformity with Taco instructions or which has been subject to misuse misapplication the addition of petroleum based fluids or certain chemical additives to the systems or other abuse will not be covered by this warranty If in doubt as to whether a particular substance is suitable for use with a Taco product or part or for...

Отзывы: