The Parasitic Elements “A”, “B”, and “E” are mounted onto the crossarm at their match marked
locations, with 2 ¼” long, 1/4” Bolts, Reinforcing Clips, Lockwashers and Nuts as shown in Figure 3.
2 in.(5.08 cm) approx.
LOCKWASHER & NUT
The antenna main Mounting Clamp is assembled to the crossarm at the unmarked holes (perpendicular
to the element holes) with 2¼” long, 3/8” diameter Hex Head Bolt as shown in Figure 4.
FIGURE 3
FIGURE 4
ELEMENT
CROSSARM
REINFORCING
CLIP
HEX HEAD SCREW
1/4-20 UNC X 2 ¼ in.
(5.72 cm) LONG
CROSSARM
HEX HEAD SCREW
3/8-16 UNC X 2¼ in.
(5.72 cm) LONG
REINFORCING CLAMP
MOUNTING PLATE
3/8 in. (.95 cm) DIA. U-BOLTS
MAST