Taco,  Inc.  will  repair  or  replace  without  charge
(at  the  company’s  option)  any  product  or  part
which  is  proven  defective  under  normal  use
within three (3) years from the date of start-up or
three  (3)  years  and  six  (6)  months  from  date  of
shipment (whichever occurs first).

In order to obtain service under this warranty, it
is the responsibility of the purchaser to promptly
notify the local Taco stocking distributor or Taco
in writing and promptly deliver the subject prod-
uct or part, delivery prepaid, to the stocking dis-
tributor. For assistance on warranty returns, the
purchaser  may  either  contact  the  local  Taco
stocking distributor or Taco. If the subject prod-
uct or part contains no defect as covered in this
warranty,  the  purchaser  will  be  billed  for  parts
and  labor  charges  in  effect  at  time  of  factory
examination and repair.

Any Taco product or part not installed or operat-
ed in conformity with Taco instructions or which

has been subject to misuse, misapplication, the
addition  of  petroleum-based  fluids  or  certain
chemical  additives  to  the  systems,  or  other
abuse, will not be covered by this warranty.

If in doubt as to whether a particular substance
is suitable for use with a Taco product or part, or
for  any  application  restrictions,  consult  the
applicable  Taco  instruction  sheets  or  contact
Taco at [401-942-8000].

Taco  reserves  the  right  to  provide  replacement
products and parts which are substantially simi-
lar  in  design  and  functionally  equivalent  to  the
defective product or part. Taco reserves the right
to make changes in details of design, construc-
tion, or arrangement of materials of its products
without notification.

TACO  OFFERS  THIS  WARRANTY  IN  LIEU  OF
ALL  OTHER  EXPRESS  WARRANTIES.  ANY
WARRANTY  IMPLIED  BY  LAW  INCLUDING
WARRANTIES OF MERCHANTABILITY OR FIT-

NESS IS IN EFFECT ONLY FOR THE DURATION
OF THE EXPRESS WARRANTY SET FORTH IN
THE FIRST PARAGRAPH ABOVE.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL
OTHER  WARRANTIES,  EXPRESS  OR  STATU-
TORY,  OR  ANY  OTHER  WARRANTY  OBLIGA-
TION ON THE PART OF TACO.

TACO  WILL  NOT  BE  LIABLE  FOR  ANY  SPE-
CIAL,  INCIDENTAL,  INDIRECT  OR  CONSE-
QUENTIAL  DAMAGES  RESULTING  FROM  THE
USE OF ITS PRODUCTS OR ANY INCIDENTAL
COSTS  OF  REMOVING  OR  REPLACING
DEFECTIVE PRODUCTS.

This  warranty  gives  the  purchaser  specific
rights, and the purchaser may have other rights
which vary from state to state. Some states do
not allow limitations on how long an implied war-
ranty  lasts  or  on  the  exclusion  of  incidental  or
consequential  damages,  so  these  limitations  or
exclusions may not apply to you.

LIMITED WARRANTY STATEMENT

120 VAC

INPUT

THERMOSTATS

BOILER

H

N

MASTER

EXISTING
ZONE
CONTROL

T

TO: "TT" ON BOILER
       AQUASTAT

AQUASTAT ON

DHW HEATER

A

Note: If Zone Control comes on without a call for heat,
reverse Reset Override input (1 & 2) wires on SR501-EXP.

ZONE

CONTROL

BOIL

SEN

OUT
SEN

BOILER SENSOR

OUTDOOR

SENSOR

PC700

JUMPER

DHW

HEATER

CIRCULATOR

CIRCULATOR

PRIMARY

CIRCULATOR

(OPTIONAL)

POWER

ZONE 1

LED

INDICATORS

FUSE

6 AMP

FUSE

6 AMP

SR 501-EXP-4

POWER

CONTROLS

SLAVE

PRIORITY ON

RESET

PRIMARY PUMP ON

POST PURGE ON

PRIORITY PROTECT ON

PUMP EXERCISE ON

30 SEC/2 WK

MASTER

OFF

OFF

OFF

OFF

OFF

NORMAL

4 MIN/24 HOUR

ACCESSORY

PORT

H

N/O

N

H

120 VAC

CIRCULATOR

PRIMARY

OUTPUT

N/C

INPUT

120 VAC

END

SWITCH

RESET

OVERRIDE

THERMOSTAT

EXPANSION

X

W

R

X

1

A

2

C

B

24 VOLTS AC ONLY

C

SINGLE ZONE

EXPANDABLE SWITCHING RELAY

FOUR ZONE SWITCHING RELAY

120 VAC CIRCULATORS

ZC   

INPUT

120 VAC

 

ZONE 1  ZONE 2  ZONE 3  ZONE 4

   ZONE1  ZONE2  ZONE3  

SR 504-4

FUSE

6 AMP

FUSE

6 AMP

FUSE

6 AMP

FUSE

6 AMP

FUSE

6 AMP

X X

R

W R

W R

W

R

W

ISOLATED

END

SWITCH THERMOSTATS (24 VAC)

PRIORITY

120 VAC

ZR

H

H

N H

N H

N H

N

H

N

H

ZONE4

ZONE 2

POWER

ZONE 1

ZONE 3

ZONE 4

LED

INDICATORS

ZONE 4

PRIORITY

OFF

ON

PRIORITY

SR501-EXP and PC700 Boiler Reset Control Connected to an Existing Switching Relay

For additional wiring diagrams, see www.taco-hvac.com.

Optional power stealing thermostat resistor part number: SRTR-001RP

(Value: 1000 Ohms, 1/2 watt or higher)

Replacement Switching Relay fuses part number: SR6A-001RP

(Manufacture: Littlefuse, Part Number: 229006)