Multi-Function LED and Troubleshooting (Red Status Lights):
This troubleshooting table is intended as a helpful guide and is not all inclusive. There could be other causes and solutions for a non-functioning product.
Only the most prominent error displays. Once addressed, the next error code will show.
LED STATUS POWER
LED STATUS
BATTERY ONLY
INDICATES
POSSIBLE CAUSE
POSSIBLE SOLUTION
AUDIBLE ALARM
Solid Green
-----------
Normal
-----------
1 Green Blink every
15 Seconds
(Approximately)
Normal
-----------
-----------
-----------
Solid Green with one red
blink
-----------
Low Batteries
Low Batteries
Replace batteries
Chirp every 60 seconds
Batteries installed incorrectly
Install batteries correctly
Chirp every 60 seconds
Not illuminated
-----------
Power off
Power supply not plugged in
Plug in power supply
-----------
------------
Not illuminated
Power off
Batteries installed incorrectly
or not at all
Install batteries correctly/
install batteries
-----------
In between cycles
Normal
Wait 15 seconds for indication
blinks
Solid Red with 2 red
blinks
Solid dim Red with
2 red blinks
Sensor error
Bad wire connection
Make sure wiring connections
are solid and tight and the
quick connect is all the way in
Chirp every 60 seconds
Make sure sensors wired per
instructions
Chirp every 60 seconds
Solid Red with 3 red
blinks
Solid Dim Red with
3 red blinks
Valve error
Valve is not connected to the
control
Connect the valve to the con-
trol
Chirp every 60 seconds
Bad wire connection
Make sure wiring connections
are solid and tight and the
quick connect is all the way in
Chirp every 60 seconds
Solid Red with 4 red
blinks
-----------
AC power error
Wrong power supply
Use power supply provided
Chirp every 60 seconds
Continuous Red blinks
Continuous Red
blinks
LeakBreaker has
Triggered
Sensor has detected water
Determine the water source
and correct. Dry the sensor
and reset the LeakBreaker.
Press the open button to
reset.
Constant alarm.
Press the mute button to
silence the alarm.
Solid Red
Solid Red
LeakBreaker has
triggered and the
water on the sensor
has dried up
Sensor has detected water
Determine the water source
and correct. Press the open to
reset.
Constant alarm.
Press the mute button to
silence the alarm.
LED STATUS POWER
LED STATUS
BATTERY ONLY
INDICATES
POSSIBLE CAUSE
POSSIBLE SOLUTION
AUDIBLE
ALARM
Solid Green w/ 1 Orange Flash
every 3 seconds
1 Orange Flash
every 3 seconds
eLink Wi-Fi
Setup Waiting
----------------
Refer to Wi-Fi set up section.
----------------
Solid Green w/ 1 Orange Blink
every
10
seconds
1 Orange Blink
every 30 seconds
Unconfigured
Refer to Wi-Fi set up section.
----------------
Solid Green w/ 2 Orange Blinks
every
10
seconds
2 Orange Blinks
every
15
seconds
Router Error
1. Can’t find router.
2. Incorrect Password
3. Incorrect SSID
Check Router.
Verify Networks Available.
Repeat Setup.
----------------
Solid Green w/ 3 Orange Blinks
every
10
seconds
3 Orange Blinks
every
15
seconds
Internet/Cloud
Error
1. Router not connected to Internet
2. No Gateway
3. Server Unavailable
Verify Internet Access is
Available.
Unplug router, plug back in.
----------------
eLink Multi-Function LED and Troubleshooting (Orange Status Lights):