Setting the Circulator Timer:
1. Set timer to exact time of day by turning the clock face
clockwise. Be sure to align the time arrow with the cor-
rect AM/PM settings in outer ring.
2. Plug power cord into nearest 115V power outlet. Set
timer manual switch to ON to test for pump operation.
Run pump in manual mode for 5 minutes to purge air
from pump. See clock face diagram.
3. To set the desired ON/OFF operation times, push the
trippers away from the clock face at the corresponding
hour/minute for ON times. Push trippers toward clock
face for OFF times. Each tripper represents 15 minutes.
4. After all ON/OFF times are set, move timer manual
switch to middle AUTO position for automatic operation.
Installing the Hot-Link Valve:
1. Select the hot water faucet furthest from the water
heater. If your plumbing system branches in two differ-
ent directions, another
Hot-Link Valve
may need to be
installed at the end of each run.
2. Shut off the hot and cold angle stop valves below the
sink.
3. Open the hot and cold faucets to purge water from the
lines.
4. Disconnect the hot and cold flex hoses from the
1
⁄
2
"
faucet connections beneath the sink and reconnect
them to the respective hot and cold inlet ports on the
Hot-Link Valve
. Locate the flow arrows on the side of
the valve to verify flow direction.
5. Install the
1
⁄
2
" x
1
⁄
2
" flex hoses provided. Connect one
hose to the hot outlet of the valve and the hot water
connection on the faucet (left side). Connect the second
flex hose to the cold outlet of the valve and the cold
water connection on the faucet (right side).
6. When all connections are made, open angle stop
valves and check for leaks.
7. Attach the
Hot-Link Valve
to the wall using anchor
screws provided.
Note:
The
Hot-Link Valve
can be disassembled for service
and cleaning. Repeat steps number 2 and 3. Unthread the
valve stem cartridge from the body and clean internal
screen of debris. Re-attach valve stem securely to prevent
leaks. Open angle stop valves and check for leaks.
Hot
Shut-Off
Valve
Shut-Off
Valve
1/2” Male
(2) New 1/2”x1/2”
Taco® supplied flex lines
(female x female)
Use (2) existing female
x female flex lines
1/2” Male
Hot-Link®
includes (2)
plastic wall anchors
& screws
Cold
1/2”
3/8” Male
3/8” Male
1/2”
HOT
COLD
Analog Timer Diagram
PR
O
G
RA
M
TR
IP
PE
RS
TIME
ARROW
MANUAL
SWITCH
IN
AUTO
SETTING
Analog Timer Manual
Switch Settings
1. Up = On, Constant
circulation
I
2. Middle = Automatic
operation
3. Down = Off O
CAUTION: Do not use pipe dope or teflon
tape on the valve body threads.
CAUTION: Use caution when attaching flex
hoses to the Hot-Link Valve to prevent cross-
threading or stripping of the threads.
Hot-Link
®
Valve
Valve Stem
Catridge
(removable)